Service diagnosis
7.4.10 Power Supply over or under voltage fault
Indoor display F19
Outdoor display: LED1 flash 6 times
5"#)#$#!6!

Domestic air conditioner
Method of
malfunction
detection
Malfunction
detection
conditions
Supposed
causes
Troubleshooting
'
Be sure to turn off power switch before connect or disconnect connector, or
else
parts damage may be caused
ƵSupply voltage not as specified
ƵThe IPM module is broken.
Ƶ The outdoor PCB is broken.
An abnormal voltage rise or fall is detected by specified voltage checking
detection circuit
An voltage signal is feedback from the voltage detection circuit to the
microcomputer
NO
House power supply fault.
Change the new one
Change the outdoor PCB
Is it rated value?
NO
YES
YES
Check the power supply
Check the IPM
module, Is it normal?