Please read this operation manual before using the air conditioner.
Ɣ
Keep this operation manual for future reference.
SPLITTYPEROOMAIRCONDITION
OPERATION MANUAL
0010580715
ER
AS07NS1HRA-WF
AS09NS1HRA-WF
AS12NS1HRA-WF
AS15NS1HRA-WF
AS09NB2HRA
AS12NC2HRA
AS18ND2HRA
AS18NS1HRA-WF
AS24NS1HRA-WF
AS15NS1HRA-GREY
AS07NS1HRA-Grey
AS09NS1HRA-Grey
AS12NS1HRA-Grey
AS18NS1HRA-Grey
AS09CB1HRA AS24NS1HRA-Grey
AS12CB1HRA
AS07NS1HRA-GU
AS09NS1HRA-GU
AS12NS1HRA-GU
AS15NS1HRA-GU
AS18NS1HRA-GU
AS24NS1HRA-GU
AS07NS1HRA-WU
AS09NS1HRA-WU
AS12NS1HRA-WU
AS15NS1HRA-WU
AS18NS1HRA-WU
AS24NS1HRA-WU
Ȼɴɥɝɚɪɫɤɢ

Questions and Answers

  • A
    andre54Aug 8, 2025
    Why is my Haier Air Conditioner not cooling properly?
    • J
      Jay RyanAug 8, 2025
      If your Haier Air Conditioner isn't cooling well, several factors could be the cause. Ensure the air filter is clean; it should be cleaned every 15 days. Check for obstructions blocking the inlet and outlet. Verify the temperature is set correctly, and that all doors and windows are closed. Direct sunlight can also impact cooling, so use curtains. Finally, consider if there are excessive heat sources or too many people in the room.
  • V
    Valerie BellAug 14, 2025
    How to change fan speed in dry mode on Haier Air Conditioner?
    • D
      Donna WatersAug 14, 2025
      In DRY mode, when the room temperature is lower than the temperature setting +2 ºC, your Haier Air Conditioner will run intermittently at LOW speed regardless of the FAN setting.
  • J
    Joel SparksAug 20, 2025
    Why does my Haier AS09NS1HRA-GU not restart immediately?
    • B
      barkermichaelAug 20, 2025
      Your Haier Air Conditioner won’t restart immediately after being stopped. To protect the system, there's a 3-minute delay. This protection circuit also activates if the electric plug is pulled out and reinserted, preventing immediate operation for 3 minutes.
  • K
    kevinshawAug 26, 2025
    Why does my Haier AS09NS1HRA-GU Air Conditioner generate smells?
    • C
      Cynthia BaileyAug 27, 2025
      The Haier Air Conditioner might circulate odors from the room, such as smells from furniture, paint, or cigarettes.
  • T
    Travis KingSep 1, 2025
    Why is my Haier AS09NS1HRA-GU Air Conditioner blowing mist?
    • J
      Jessica HallSep 1, 2025
      During COOL or DRY operation, your Haier Air Conditioner may blow out mist due to the sudden cooling of indoor air.

Haier AS09NS1HRA-GU Specifications

General IconGeneral
Cooling Capacity9000 BTU/h
Energy Efficiency Ratio (EER)3.21
Power Supply220-240V, 50Hz
RefrigerantR32
Weight (Indoor Unit)8.5 kg
Air Flow (High)500 m³/h
Noise Level (Indoor)38 dB(A)
TypeSplit System
Operating Temperature (Cooling)18°C to 43°C