Loading...
Service diagnosis
Domestic air conditioner
27
10.3 Error Codes and Description indoor display
Only For 498 and
498A display
(Red/Green Time
Run
On
FlashOff)
Indoor and
Outdoor
E7
Directly display
15
Communication fault between
indoor and outdoor units
Page.36
E1
Directly display
/
Indoor temperature sensor failure
Page.28
E2
Directly display
/
Indoor coil sensor failure
Page.28
E4
Directly display
/
Indoor eeprom failure
Page.29
E14
Directly display
/
Indoor fan failure
Page.30
E5
Trouble record
22
Internal unit antifreeze
protection
/
E9
Trouble record
21
Internal unit overload
Page.39
F12
Directly display
1
Eeprom failure
Page.29
F1
Directly display
2
IPM failure
Page.31
F22
Directly display
3
AC current overcurrent
protection
Page.32
F3
Directly display
4
Communication error between module
board and main PCB board
Page.33
F20
Trouble record
5
High pressure protection
/
F19
Trouble record
6
Power over/under voltage
protection
Page.34
F27
Directly display
7
Compressor stall / press
instantaneous stop
/
F4
Directly display
8
Compressor discarging temperature
protection
Page.35
F8
Trouble record
9
Abnormal of DC motor
Page.30
F21
Directly display
10
Abnormal of piping sensor
Page.28
F7
Directly display
11
Suction temperature sensor
failure
Page.28
F6
Directly display
12
Abnormal of outdoor ambient sensor
Page.28
F25
Directly display
13
Abnormal of compressor discharge
sensor
Page.28
F13
Trouble record
16
Lack of refrigerant
/
F14
Trouble record
17
4-way valve reverse failure
/
F11
Directly display
18
Compressor jam (only for spdu)
Page.38
F28
Directly display
19
Module PWM select circuit error
Page.38
F15
Trouble record
20
Outdoor terminal block
temperature protection
/
F2
Trouble record
24
Instantaneous over-current
protection of the compressor
Page.32
F23
Trouble record
25
Compressor U-phase overcurrent
Compressor V-phase overcurrent
Compressor W-phase overcurrent
Page.32
F9
Trouble record / 26
Module reset
/
F24
Trouble record
27
CT disconnection
/
F34
Trouble record / 37
Outdoor coil protection
/
F35
Trouble record
38
Compressor driver board failure
/
F43
/
46
Model matching abnormality
/
Indoor
Malfunction
Outdoor
Malfunction
fault description
Reference
Page
Other display
Indoor displaying panel code
indication
Code indication
Outdoor
(LED1
flash
times)

Related product manuals