19
5
Corresponding saturation temperature of sensor Pd
7
Opening of outdoor unit PMV1
(decimal number):
( )(decimal number)
( )(decimal number)
Notice: Value Pd in cooling mode as well as value Pd in heating mode is of no consequence in AU362FIAIA model.
SV2 hand setting of outdoor unit PMV2 of AU362FIAIA: Open: FF, Closed: 00
SW01 SW02
4
6
0
1
2
3
8
9
10
11
1
12
13
14
2
0
1
2
3
4
5
6
7
8
9
9
10
11
4
5
6
7
8
9
10
11
Indoor unit capacity (Pi): NEW CODE : 0 denote 0.8(pi) ; 1 denote 1(pi) ; 2 denote 1.2(pi)
Saturation temperature ( ) of indoor unit (Decimal number) : -26.0~67.0
Sensor temperature ( ) of indoor unit TA (Decimal number): -26.0~67.0
Sensor temperature ( ) of indoor unit TC2 (Decimal number): -26.0~100.0
Sensor temperature ( ) of indoor unit TC1 (Decimal number): -26.0~100.0
Display of numeral pipe with seven segments
Sensor TD Air Discharge value ( )(decimal number):
Sensor TA Environment timP. value ( )(decimal number):
Sensor TS Air suction value ( ) (decimal number):
Sensor TE Defrost value ( )(decimal number):
Sensor TC middle part of Condenser value ( )(decimal number):
Corresponding saturation temperature of sensor Ps
(Model AU362FIAIA don't have).
Magnet valve SV2: ON: Non 0 OFF: 0
On position of 2-way valve SV1 display ON: -1, OFF: --
Current value of compressor when operating(decimal number)
Blower fan mode of outdoor Low speed: -1 Medium speed:-2 High speed:-3
Status of temperature sensor: ON: -1, OFF: --
On position of 4-way valve display: ON: -1, OFF: --
Force setting of operating mode status: Cooling: -C Heating: -H
No used
Opening hand setting of outdoor unit PMV1: All open: FF, All closed: 00
Opening hand setting of outdoor unit PMV2: All open: FF, All closed: 00
Rated operation setting: Rated operation: -F, Common: --
Communicating status of indoor unit: Normal signal receiving: -1, Abnormal signal receiving: --
Check code of indoor unit: No check code of indoor unit: --
Required capacity of indoor unit (Decimal number): indoor P-CODE
Opening of indoor unit PMV (Decimal number):
Check fault in the electrical circuit Cooling operation:CC (old code have no)
Check fault in the electrical circuit Heating operation: HH (old code have no)
unification trial run of cooling operation: C (old code have no)
unification trial run of heating operation: H (old code have no)
unification trial run of auto operation: _F (old code have no)
All open/close :open 11/close 00 (after three minutes display-- )(old code have no this function)
Function of clean abnormity CL(old code have no)
0-7
8
Opening hand setting of outdoor unit PMV: All open and All closed function All open: FF
Display amount of the indoor units ,display 6 denote have six indoor units :
3
0-15
0-15
3 denote 1.5(pi) ; 4 denote 2(pi) ; 5 denote 2.5(pi)
6 denote 3(pi) ; 7 denote 4(pi) ;
OLD CODE : 1 denote 1(pi) ; 7 denote 7(pi)
12
13
0-15
0-15
0-15
1-16
1-16
1-16
1-16
1-16
Single unit cooling operation trial run
Single unit heating operation trial run
calculate according to the compressor suction pressure(PS).
Others and Test Run