Loading...
power on
power on
partial
signs
display dehumification sign, emission sign, 8 sign, OFF sign, up arrow, down arrow
Selection of
emission
code
press
"select"
button
new code selection: press "select" button once, there is up arrow in the LCD, which shows the
new code will be selected. We always use new code.
Old code selection: pree "select" button again, there is down arrow in the LCD, which shows the
old code will be selected.
read unit
code
Press "read" button once, emission sign and deumification sign will keep for 1 second, read the
indoor unit number, and observe that the flash time of power lamp of indoor unit should
correspond with the data in the LCD.
set No. 1
unit
Press "No. 1" button, 1 will flash, then press "SET" button at indoor unit. When a sound "du" of
indoor unit is heard, unit 1 is set, then press "READ" to confirm if the unit number is right.
set No. 2
unit
Press "No. 2" button, 2 will flash, then press "SET" button at indoor unit. When a sound "du" of
indoor unit is heard, unit 2 is set, then press "READ" to confirm if the unit number is right.
set No. 3
unit
Press "No. 3" button, 3 will flash, then press "SET" button at indoor unit. When a sound "du" of
indoor unit is heard, unit 3 is set, then press "READ" to confirm if the unit number is right.
set No. 4
unit
Press "No. 4" button, 4 will flash, then press "SET" button at indoor unit. When a sound "du" of
indoor unit is heard, unit 4 is set, then press "READ" to confirm if the unit number is right.
set No. 5
unit
Press "No. 5" button, 5 will flash, then press "SET" button at indoor unit. When a sound "du" of
indoor unit is heard, unit 5 is set, then press "READ" to confirm if the unit number is right.
set No. 6
unit
Press "No. 6" button, 6 will flash, then press "SET" button at indoor unit. When a sound "du" of
indoor unit is heard, unit 6 is set, then press "READ" to confirm if the unit number is right.
set No. 7
unit
Press button 6 and at the same time in 2 seconds press button 1, then loosen them
simultaneously. The LCD will display “7”, which stands for selecting unit 7. And then press button
“set”, you can set unit 7.Then press "READ" to confirm if the unit number is right.
set No. 8
unit
Press button 6 and at the same time in 2 seconds press button 2, then loosen them
simultaneously. The LCD will display “8”, which stands for selecting unit 8. And then press button
“set”, you can set unit 7.Then press "READ" to confirm if the unit number is right.
lock unit
number
Confirm the whole air conditioner work normally, then lock all indoor unit number by "LOCK". The
locked unit numbers will not change if without the address setting controller.
press
"select"
button
new code selection: press "select" button once, there is up arrow in the LCD, which shows the
new code will be selected. We always use new code.
Old code selection: pree "select" button again, there is down arrow in the LCD, which shows the
old code will be selected.
read unit
code
Press "read" button once, emission sign and deumification sign will keep for 1 second, read the
indoor unit number, and observe that the flash time of power lamp of indoor unit should
correspond with the data in the LCD.
set No. 1
unit
Press "No. 1" button, 1 will flash, then press "SET" button at indoor unit. When a sound "du" of
indoor unit is heard, unit 1 is set, then press "READ" to confirm if the unit number is right.
set No. 2
unit
Press "No. 2" button, 2 will flash, then press "SET" button at indoor unit. When a sound "du" of
indoor unit is heard, unit 2 is set, then press "READ" to confirm if the unit number is right.
set No. 3
unit
Press "No. 3" button, 3 will flash, then press "SET" button at indoor unit. When a sound "du" of
indoor unit is heard, unit 3 is set, then press "READ" to confirm if the unit number is right.
set No. 4
unit
Press "No. 4" button, 4 will flash, then press "SET" button at indoor unit. When a sound "du" of
indoor unit is heard, unit 4 is set, then press "READ" to confirm if the unit number is right.
set No. 5
unit
Press "No. 5" button, 5 will flash, then press "SET" button at indoor unit. When a sound "du" of
indoor unit is heard, unit 5 is set, then press "READ" to confirm if the unit number is right.
After dehumification sign, emission sign, 8 sign, OFF sign, up arrow, down arrow display for 3 minutes, the
controller will only display up arrow and down arrow
operr
ation of old code setting
Function table for address setting controller
operation of new code setting
Note: When setting unit number, if indoor unit sounds "du du", which shows this number has exixted in the
system, you should set another unit number.