107
HBS1
HBS2
CN15
F01
J80
CN24
SW05
1 13
2
R25
CN22CN21
TC1BTC1ATC2
CN05
131313
CN04
T A
1
1
2
6
P-SENSOR
CN23
3
1
CN27
C07
IC1112VB
F02
CAPACITY
I/O UNIT No.
SW01
RB05
X03
RB06
CB01
IC12
GND
C41
C09
C40
CB02
IC06
16
1 13
12
9
8
TC4051BP TB1035N
5V
C02
D08
D10
TLP
521
4
3
1
2
3
1
4 6
TLP
541G
IC13
B1
B3
B2
B2
B2
B3
B
A C
132
CN02
CN12
1 1
2
4
CN01
TRANS2
LOUVER
CN26
1 2
1
R18
R17
R20
IC16
C04
2
3
12V
IC16
C12
IC10
C106
IC03
B
E
C
12
1313
1
24
33
RB15
C01
DB01
J70
4 1
5
8
IC02
TB1035N
C101
C104
C116
X02
RB16
IC04
X01
24
1
1
IC07
CB04
32
30
CLOCK1
CN32
RB13
C111
CB03
RB14
TC4051BP
16
9
8
RB08
SW03
C114
1 3
C24
4 1
J01
J02
J03
J04
J05
J06
RB12
RB11
RB04
IC01
J01
J08
J09
J10
J11
RB10
RB09
RB02
J13
J14
J15
J16
J17
J18
RB07
SW06
CN19
IC05
CN17CN06
HA
1
2
3 1
6
CN25
PMV
1 2-CEILING HEIGHT
1
R47
R46
6
CN13
IC08
10
1
16
1 1
C32
10
D17 D16
RB03
IC09
1 1
TD62CB52P
TD62CB52P
SW02
25 20 15 10 5
35 45 50 55 6040
RB17 RB01
CN14
C25 C50
1
8
R30
1 2
34
IC14
R99
TLP
621
J71
7 1
CN10
CN18
1 3
FAN IN
PUMP
1
1
3
1
COMPONENT SIDE
TLP665JF
6
4
20
1
SW07
R94
R95
IC15
20
J23
J22
J21
J20
J19
CN31
ON
OFF
L03
RY05
CN30
SW04
R97
TEMPORARY
OPERATION
RY07
RY01
CR04
R31
SG01
CN09
D12
E5
CN03
N L
3 1
LVR
RY06
64
1
LAN ADDRESS
R100
R98 R96
D64
G
T2
T1
1SR
RP
C71
CN07
FAN
MCC-1333-02
Haier
C67
C69
CR02
CN08
HEAT
1
S1
7
R32
CN16
TRANS1
1
3
1 2-TR ADJUSTMENT
3-TMN MODE
TD62308BP
Communication terminal of
outdoor unit(BUS)
Communication
terminal of central
control
(BUS)
TC1A
sensor
input
TC2
sensor
input
TA
sensor
input
Pressure sensor
input (High
pressure side)
Pressure sensorinput (Low
pressure side)
serial signal input
instruction LED(orange) from wiercontroller
serial signal inputinstruction LED(green) from wiercontroller
+12VB
Power
supply of
pressure
sensor
+5V power supply
+12V power supply
Setting switch ofindoor HP (SW05)
Watchdog timingoutput (CPU25PIN)
Serial communication input ofremote controller (CPU20PIN)
SW01 Setting
switch of indoor
unit number
(group)
(swol)
Setting switch of
heating temperature
(SW03)
compensation
HA input (CPU62PIN)
Float switch input
(CPU61PIN)
Setting switch ofairflow modification(SW06) rate
compersation
All stop abnormal LED (red)
Outdoor unit BUS
communication input LED
(Yellow)
Phase fixing output switching (J14)
Modification voltage of pressure sensor*CPU59PIN*
Serial signal output of remote controller (CPU20PIN)
HA output (CPU53PIN)
Zero cross detection (CPU 17PIN)
Fan
output
Emergency
running
switch
(SW04)
Setting switchof contral
control
address
(1)Inspecting point of indoor unit PCB MCC-1333-02
(Speed regulating type of silicon control)
15. Indoor unit circuit
Все каталоги и инструкции здесь: http://splitoff.ru/tehn-doc.html