b. Wiring diagram of AU96NFTAHA outdoor unit
18
*
309
*
309
5 5
1 3 5
2 4 6
A
B
1 3 5
2 4 6
A
B
1 2 3
4 5 6
3
1
1
2
2
21
43
ON
600V 20A
600V 20A
600V 20A
L1
L2
L3
N
FM1
FM2
3
1
3
1
2
2
6
6
5
5
7
7
Power 380-415V,3N, 50HZ
SV4
SV2
1 2 3
ON
SW03
1 2 3
ON
SW06
SW04 SW05
SW01 SW02 SW07
2
2
4
4
1
1
3
3
pressure sensor
high pressure(PD)
reactor
reactor line
assembly
L1
L2
Y
Y
noise filter
1 2
3 4
2
3
(+) (-)
(-)(-)(-)
R
P03
P02
P01
P04
MCC-1253
F2
600V 7A
600V 7A
noise filter
52C1
52C3
F1
1 3 5
21 A2
A1
52C2
51C
2 4 6
22 95
96
CM2
surge
absorber
Y
reversal phase
protective relay
PMV
PMV
Function explanation of dail switch (MCC-1332)
shielding line ear thing
FM1
RC01
RC02
FM2
GR
PTCPTC
R
R
R
R
R
GR
noise
filter
1 2
3 4
noise
filter
TD1
TD2
TS
CN01
CN07
CN02
CN03
CN05
CN14
TE
CN10
CN06
CN18 CN51 CN50
CN24 CN25 CN19 CN20
MCC-1332
W
R
CN08 CN17
BL
CN28 CN27 CN09
D42 D43
CM2
Code
Name
CM1
52C1
52C2
52C3
PMV
63H1,63H2
RC01,RC02
SV2,SV4
20SF
CH
F1,F2,F3
49C1,49C2
51C
TD1,TD2,TS,TE
TRS
displalfed information
SW01
SW02
0
0
1
4
5
6
7
9
10
11
12
14
15
0
1
2
3
4
5
6
7
1
Displayed information
SW01 SW02
2
0
1
2
3
4
SW01
3
4
5
9
11
12
13
15
Displayed information
external instruction operation state,external instructionoperation: 1
operation mode of external option, cooling: C; heating : H
intergrated operation start and stop : start: 1 stop: 0
control state of the fan speed prevent snowing
control state of low -noise operation at night in control: 1
0-15
0-15
0-15
0-15
0-15
0-15
0-15
0-15
SW02
+
-
+
-
+
_
+
_
W
V U
G-Tr
EZ BZ EY BY EX BX
EW BW EV BV EU BU
MCC-1252
1
3
7
52 4 6 8
2
2
3
3
5
5
1
1
1
1
3
3
2
2
4
4
1
1
3
3
1
1
3
3
5
5
7
7
1
1
3
3
ON
1 2
SW01
CN01
D25 D26 D27 D28
CN13
CN12CN04CN05CN16CN17
CN15
CN07
CN06
CN20
CN24 CN23
P 0 1
P 0 2
CN22 CN25
CN21
TRS
MCC-1331
U
V
W
U
V
W
CM1
inverter
20SF
49C2
SW
03
06
07
1
2
3
1
2
3
1
1 2
1 2
1 2
1 2
ON
ON
ON
ON
LED
ON OFF
CH
CH
49C1
CN12
CN16
CN11
B
CN13
pressure sensor
low pressure(PS)
BL
W R
resistor
capacitor
resistor
capacitor
diode
GR
BL
Y
R W B W B
R W B
R
W
B
B
B
R
W
B
B
R
W
R
GR
BL
BL
W
GR
W
BL
W
W
R
W
W
R
W
BL
B B B
W
Y
R W B
R W B
surge absorber
A C, current sensor
Compressor (inverter)
Compressor (commercial)
magnetic contactor (CM1)
magnetic contactor (CM2)
magnetic contactor (CM1)
electronic expanding valve
high pressure switch
capacitor(for FM01,FM02)
2way-valve solenoid valve
4way-valve solenoid valve
crankcase heater for compressor
fuse(20A 600V)
inside overload protector(IOL)
overload protector (OL)
temp sensor
thermostat 100*
Notes:please connect the outdoor unit to the power,
then connect the indoor unit to the power
otherwise,the failure code[95]may appear
At this time press the "self-check''button on the wired controller for at least 10 senconds to delete the failure code.(The machine's operation will not be influenced by such a phenomenon)
failure code for outdoor unit
operational mode,cooling:C,heating:H,defrosting:J
INV target frequency
INV real frequency
number of the indoor units connected
outdoor unit is in the sensor back-up operational state
confirm mis -wired(cooling operation),press sw04 for at least 2 seconds
confirm mis-wired(heating operation),press SW04 for at least 2 seconds
cooling test run,pressSW04 at least2 seconds
heating test run, pressSW04 at least 2 secondsintegrated operation start and stop start: SW04 stop: SW04
conftrm operation of indoor remote controller start: SW04,stop: SW05
data of TD1
data of TD2
data of TS
data of TE
data of Pd
data of Ps
PMV open degree of outdoor unit
operation state of rated press operation:1
room units communication state information receiving l: 1
room units failure code
room units capacity code
room units PMV open degree
room units TA sensor data
room units TC2 sensor data
room units TCIA sensor data
room units separate test run start:SW04,stop:SW05,
press the button for at lest 2seconds
(The''0-15''under SW02 is the addresses of indoor unit)
Unit
function
back- up operation upon compressor(inverter)failure fault
nack- up operation
normal
back- up operation upon compressoncy compressor(commercial)failure
external contrd switch
snowing fan control
back -up operation upon pd sensot failure
back -up operation upon ps sensor failure
not used
not used
Switch SW01&ED Displayed Information(MCC-1331)
Switch
1 red (D25)
2 yellow (D26)
3 yellow (d27)
4 yellow (D28)
Overload protective
circuit of GTR
compressor system
current
detect
protection
high- pressure
switch system
circuit
Frequency data of serial signal(sending to MCC-1332)
current detect
circuit
times of
protecting action
Frequency data of serial signal(receiving from MCC-1332)
1. Dotted line for field wiring.2. for terminal block,the numbers inside for the terminal numbers.3. for printed circuit board.
R W B
BL OR
Y
R
W
W
B
W
R
BL
B
W
R
BL
BL
R
R
W
OR
rectifier
R
R
W
B
BL
R
B
B
W
R
R
B
resist
resist
resist
B BL B W
B
R BL W R
Y
BL
B
B
R
B
B
B
B
BR
OR
B
R
W
W
OR
Y
BL
W
BL
R
BL
Y R
B
BL
63H1
W
W
R
R
Y
B
R
W B
Y
BL
R63H(INV)
63H2
6 3 H
1 2
4WV
SV2,SV4
4 9 C
250V 20A
F 3
W
B
B
W
R
r
6
5
4
3
2
1
1 2
1 1
1 0
9
8
7
R
W
B
Y
~
diode
B
M R R B B
G R G R
B
R
W
R
W
BL
R
GR
CN15
R
7
6
5
7
6
5
B
W W
D,C,current sensor
W
B
W
back- up operation
external control
back- up operation
back- up operation
back- up operation
normal
normal
normal
normal
normal
circuit
6
5
4
3
2
1
12
11
10
9
8
7
2
2
4
6
4
6
1
1
2
2
4
6
4
6
1
1
2
2
4
4
1
1
3
3
2
2
4
4
1
1
3
3
2
2
4
4
1
1
3
3
8
8
1 1
33
1 1
33
1 1
22
1 1
22
1 1
33
2
2
4
4
1
1
3
3
5
5
3
3
1
5
1
5
7
7
3
3
1
5
1
5
7
7
3
3
1
5
1
5
3
3
5
5
1
1
2
2
3
4
4
3
3
3
1
5
1
5
*
309
*
309
1
2
1
2
1
2
1
2
1
2
1
2
3
3
1
1
2
2
4
4
3
3
1
1
2
2
4
4
3
3
4
4
1
1
2
2
1
2
21
2
1
1
21
1
2
2
2
1
1
2
P
Q
P
Q
1
1
3
3
1
1
3
3
1
1
3
3
1
1
3
3
7
3
1
5
1
1
3
3
1
1
3
3
7
7
5
5
9
9
2
2
4
4
6
6
8
8
1
1
3
3
7
7
5
5
9
9
2
2
4
4
6
6
8
8
1
1
3
3
7
7
5
5
9
9
2
2
4
4
6
6
8
8
1
1
3
3
1
1
3
3
1
1
3
3
1
1
3
3
1
1
3
3
3
3
1
5
1
5
3
3
1
5
1
5
7
3
1
5
1
1
3
3
1
1
3
3
1
1
3
3
1
1
3
3
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
Y
B
1
3
4
5
6
1
3
4
5
6