EasyManua.ls Logo

Haier HP110M5 - User Manual

Haier HP110M5
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Heat pump Water Heater
Operation and Installation Manual
Model
HP80M5
HP110M5
Please read this manual carefully prior to
your use of this water heater.
The appearance of the water heater given
in this manual is for reference only.
English
ELECTRICITE
Question and Answer IconNeed help?

Do you have a question about the Haier HP110M5 and is the answer not in the manual?

Summary

Safety Instructions

Interpretation of Marks and Symbols

Explains symbols used in safety instructions for user and product safety.

Technical Specifications

Installation Introduction

Installation Precautions

Lists essential precautions before installing the water heater.

Installation Dimensions

Unit Size and Mounting Data

Provides detailed dimensions and guidance for mounting the unit.

Air Connection

Advised Positions

Installation Cautions

Pipeline Installation Diagrams

Electrical Connections

Safety Precautions and PV Integration

Outlines safety measures for electrical connections, including PV system integration.

Off-Peak Power Signal Wire

Wiring Diagram and Commissioning

Operation and Functions

System Protections and Features

Details built-in protections like leakage, overload, and defrosting, plus functions like anti-freezing.

Installer Settings

Checking and Maintenance

Safety Valve and Hydraulic Checks

Instructions for checking the safety valve and hydraulic circuit for proper function and leaks.

Faults and Protection Codes

Compressor and Electrical Faults

Lists fault types, actions, and digital indications for compressor and electrical issues.

Sensor and Communication Faults

Details fault codes related to temperature sensors, communication, pressure switches, and fan.

Product Fiche

Summary

Safety Instructions

Interpretation of Marks and Symbols

Explains symbols used in safety instructions for user and product safety.

Technical Specifications

Installation Introduction

Installation Precautions

Lists essential precautions before installing the water heater.

Installation Dimensions

Unit Size and Mounting Data

Provides detailed dimensions and guidance for mounting the unit.

Air Connection

Advised Positions

Installation Cautions

Pipeline Installation Diagrams

Electrical Connections

Safety Precautions and PV Integration

Outlines safety measures for electrical connections, including PV system integration.

Off-Peak Power Signal Wire

Wiring Diagram and Commissioning

Operation and Functions

System Protections and Features

Details built-in protections like leakage, overload, and defrosting, plus functions like anti-freezing.

Installer Settings

Checking and Maintenance

Safety Valve and Hydraulic Checks

Instructions for checking the safety valve and hydraulic circuit for proper function and leaks.

Faults and Protection Codes

Compressor and Electrical Faults

Lists fault types, actions, and digital indications for compressor and electrical issues.

Sensor and Communication Faults

Details fault codes related to temperature sensors, communication, pressure switches, and fan.

Product Fiche

Overview

This document is an operation and installation manual for a Haier Heat Pump Water Heater, specifically models HP80M5 and HP110M5. It provides comprehensive information on the device's function, technical specifications, usage, and maintenance.

Function Description

The Haier Heat Pump Water Heater utilizes a heat pump system to efficiently heat water. A low-pressure liquid refrigerant is vaporized in the evaporator and then compressed, increasing its temperature. This heated refrigerant then flows through a condenser coil within the storage tank, transferring its heat to the water. As the refrigerant cools and condenses, it passes through an expansion valve, reducing its pressure, and the cycle repeats. This process allows for energy-efficient water heating by extracting heat from the ambient air. The appliance also includes an electric backup heater for faster heating or when the heat pump alone is insufficient. It features various operating modes, including Auto, ECO (off-peak), Electric heating, and Holiday mode, to optimize energy consumption and user comfort. Safety features include electrical leakage protection, 3-minute protection for the compressor, automatic defrosting, overload protection, and an anti-freezing function.

Important Technical Specifications

The manual details specifications for two models: HP80M5 and HP110M5.

General:

  • Rated Voltage/Frequency: 220V~240V/50Hz for both models.
  • Tank Rated Pressure: 0.8MPa for both.
  • Corrosion Protection: Magnesium rod for both.
  • Waterproof Grade: IPX4 for both.
  • Refrigerant Type/Weight: R134a/0.45kg for both.
  • Max Working Pressure of Refrigerant: 0.8/2.8MPa for both.
  • Sound Power Level: 50dB for both.
  • Ambient Temperature for Use of Product: -7~45°C for both.
  • Operating Temperature of Heat Pump: -7~45°C for both.
  • Maximum Length of Air Duct: 5m for both.
  • Diameter of Air Duct Connection: 160mm for both.
  • Inlet Water Pressure: 0.1-0.5MPa.
  • Suggested Inlet Water Temperature: 10-30°C.

Model Specifics:

Specification HP80M5 HP110M5
Tank Volume 82L 105L
COP@7°C / EN16147 2.74 2.73
COP@14°C / EN16147 3.04 3.02
Tapping Cycle M M
Power Input by Electric Backup 1200W 1200W
Rated Power Input by Heat Pump 240W 240W
Maximum Power Input by Heat Pump 350W 350W
Maximum Power Input 1550W 1550W
Standby Power Input/Pes 21W 21W
Max Volume of Usable Hot Water at 40°C (setting at 55°C) 103L 132L
Heating Up Time (7°C) 5h07 6h38
Heating Up Time (14°C) 4h35 5h56
Default Temperature Setting 54°C 54°C
Temperature Setting Range (with heater) 35°C-75°C 35°C-75°C
Product Dimensions (WDH) 4925371170mm 4925371320mm
Packing Dimensions (WDH, without pallet) 5875871247mm 5875871397mm
Net/Gross Weight 52/59kg 65/73kg
Water Inlet and Outlet Connection G1/2"M G1/2"M
Safety Valve Connection G1/2"M G1/2"M
Drain & Water Inlet Connection G1/2"M G1/2"M
Water Heating Energy Efficiency (wh) 115% 115%
Water Heating Energy Efficiency Class A+ A+
Annual Energy Consumption (AEC) 443 kWh/annum 444 kWh/annum
Daily Electricity Consumption (Qelec) 2.13 kWh 2.14 kWh
Mixed Water at 40°C 103 L 132 L
Load Profiles of Water Heaters, Type M M

Usage Features

The water heater is designed for user-friendly operation with a clear display panel and intuitive controls.

  • Operating Modes:
    • Auto Mode: Optimizes heat pump and electric heater management for guaranteed comfort, prioritizing the heat pump and activating auxiliary power if the compressor runs continuously for more than 8 hours (adjustable in installer settings).
    • ECO (Off-peak) Mode: Prioritizes the heat pump, with two options for activation: timer-based (referring to LP parameter) or switch signals from power companies.
    • Electric Heating Mode: Activates the electric heating function to ensure hot water supply when the heat pump is not operating optimally.
    • Holiday Mode: Allows users to pre-set vacation dates and desired temperature, with the heat pump automatically starting heating at 00:00 on the fourth day before return.
  • Boost Mode: Activates both the heat pump and auxiliary power simultaneously for rapid heating (available only in Auto mode).
  • PV Function: When enabled and an effective PV signal is received, the setting temperature automatically adjusts to 65°C, and both the heat pump and electric heating are turned on.
  • SG Signal: Upon receiving an SG signal, the setting temperature automatically adjusts to 65°C, and the heat pump heats according to this logic.
  • Peak/Off-peak Hours Mode: Displays the "HC" symbol when active, indicating peak/off-peak hours.
  • Anti-legionella Function: Automatically activates every 7 days to heat the tank to 65°C, preventing Legionella bacteria growth.
  • Temperature Setting: Default temperature is 55°C, with a setting range of 35°C-75°C when the heater is active.
  • Installer Settings: A dedicated menu (accessed by pressing power off, then '+' and 'SET' for 10 seconds) allows professional installers to configure advanced parameters such as off-peak signal type, off-peak logic type, anti-legionella activation, compressor maximum continuous working time, day of the week setting, and auxiliary heating in off-peak time.

Maintenance Features

Regular maintenance is crucial for optimal performance and extended lifespan of the water heater. All maintenance and electrical connections must be performed by qualified professionals with the power supply disconnected.

  • Safety Valve Check: Operate the safety valve at least once every six months to ensure proper functioning. Replace if blocked or malfunctioning. The water drain pipe connected to the safety valve must be open to the atmosphere, unblocked, and installed in a frostless environment with a continuous downwards inclination.
  • Hydraulic Circuit Check: Verify the watertightness of all water connections.
  • Fan Cleaning: Check the cleanliness of the fan annually.
  • Evaporator Cleaning: Clean the evaporator regularly using a soft-haired brush. Carefully realign bent fins to avoid affecting performance. Caution is advised due to sharp fins.
  • Condensate Discharge Pipe Check: Ensure the pipe is clean and free of obstructions to prevent poor condensate flow or water accumulation in the heat pump's plastic base.
  • Magnesium Rod Check: The magnesium anode should be checked every 2 years and replaced in time to prevent tank corrosion. In areas with poor water quality, the checking interval should be shortened.
  • Draining the Water Tank: To drain the tank, cut off the power supply, shut down the water inlet valve, and then drain via the sewage outlet. Exercise caution as the water may be hot.
  • Fault Indication: The display panel provides digital indications (e.g., F2, E1, L7) for various faults such as operating temperature protection, electricity leakage, over-temperature, sensor faults, communication faults, pressure switch protection, ambient temperature protection, and fan faults, aiding in troubleshooting. After a fault is resolved, switching the power supply on will release the error.