Functions Setting
This portable air conditioner has three functions: cooling, dehumidifying and fan. Fan
has two speeds: high speed and low speed, setting temperature is 17--30℃(62~86
℉), 24 hours timer, sensor and water-level protective function.
Buttons:There six keys on the control panel: POWER,Mode,Fan Speed, Timer, Up key and
Down key .
a). POWER Key: Press the key to start the unit ,and press this key again to turn unit off.
b). Mode Key: Set the Cooling , Dehumidifying and Fan Mode when unit is working or
Timer-On Situation.
c).Fan Speed: From pressing the button , fan speed change by low - high - low loop
manner, but not available in dehumidifying mode.
d). Timer Key: Can set the Timer-Off function in unit working situation, when setting the
time,the Regular time indicator will illumine; can adjust the time again while the Regular time
indicator will illumine; then it will display the room temperature again in the Off mode. Can also set in the
Timer-On function,same as above setting.
After the Timer-Off or the Timer-On, the Timer indicator lights.
e).Up\Down Key: Press this two key to set the desired room temperature.(Press the Up
key once,the temperature will increase by 1℃ or 1℉, also press the down key to decrease by 1℃ or 1℉),
can also set the time in Timer Situation; can also exchange from ℃ to ℉ display by pressing these two
* the user wants to display the temperature in ℃, you can use the button on the remote controller or press the
up and down key simultaneously.
Operation instructions:
a) In the Cooling models:
Ta≥Ts+1℃ (1℉), the cooling starting.
Ta≤Ts-1℃ (1℉), the compressor stops and only the fan motor remains working at
the set fan speed.
Ta:Room Surrounding Temperature Ts:Setting Temperature
In the mode,pressing Timer and Down button can set sleep function, In sleep
function, After operating two hours, the set temperature increases 1℃(1℉)
automatically. After operating for another 2 hours, the set temperature will
increase 1℃(1℉) again. Then, the set temperature will not change and the
fan is forced to switch to low level.