Sensor name
Sensor
marker
Sensor location Function
RT sensor RT SNR under the right hinge box
measure the temp. of the
circumstance
Refrigerator sensor 1 R1 SNR beside the air-vent in REF measure the temp. of the air
Refrigerator sensor 2 R2 SNR on the right side of the REF cabinet
measure the temp. of the REF
compartment
Icemaker sensor ICE SNR under the ice box in FRZ measure the temp. of the ice box
Defrosting sensor D SNR on the top of the evaporator in FRZ measure the temp. of the evaporator
Freezer sensor F SNR middle of freezer compartment
measure the temp. of the FRZ
compartment
Error code list:
Error Indicator
NO Malfunction
F SET R SET
Error code meaning
1 F SNR failure F4 normal F SNR is short circuit or open circuit
2 RT SNR failure normal F3 RT SNR is short circuit or open circuit
3 R1 SNR failure normal F1 R1 SNR is short circuit or open circuit
4 R2 SNR failure normal F2 R2 SNR is short circuit or open circuit
5 D SNR failure normal F6 D SNR is short circuit or open circuit
6 ICE SNR failure normal F7 ICE SNR is short circuit or open circuit
7 Freezer fan motor failure normal E1 more than 30 seconds without signal
8 Condenser fan motor failure normal E2 more than 30 seconds without signal
9 failure communication normal E0
No reflect when setting ,between
display PCB and Power PCB no signal
transmitted over 2 min
10 Defrosting system failure normal Ed can not reach -12ć within 2 hours
11 Icemaker failure normal Er icemaker defective
