EasyManua.ls Logo

Haier HRF-800DGS8 - Appliance Storage and Power Interruption

Haier HRF-800DGS8
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SERVICE MANUAL
Model: HRF-800DGS8
20
Issue 2014-11-13
REF. Ref1411S025V1
Error code lise:
NO
Malfunction
Error
Indicator
Error code meaning
1
normal
-- --
2
RT SNR failure
F2
RT SNR is short circuit or open
circuit
3 F SNR failure
F3
F SNR is short circuit or open
circuit
4 R SNR failure
F4
R SNR is short circuit or open
circuit
5
REF defrost sensor failure
F1
REF defrost sensor is short circuit
or open circuit
6 FRZ defrost sensor failure
F6
FRZ defrost sensor is short circuit
or open circuit
7 My zone sensor failure
F5
My zone sensor s short circuit or
open circuit
9
failure communication
E0
No reflect when setting ,between
display PCB and Power PCB no
signal transmitted over 2 min
10
Freezer fan motor failure E1 Freezer fan motor low rev
11 Cooling fan motor failure
E2
Cooling fan motor low rev
12
REF fan motor failure
E6
REF fan motor low rev
13 REF defrost failure
EC
REF defrost display lower 7 when
REF defrost heater work more zhan
60minute
14 FRZ defrost failure
Ed
FRZ defrost display lower 7 when
FRZ defrost heater work more zhan
60minute
Attention:These error codes cannot be displayed automatically)
E0>EC>Ed>F3>F1>F6>F2>F4>F5>E1>E2>E6