As shown in the above diagram,after running for 1 hour under refrigerating mode
and dehumidification mode,the setting temperature will increase 1
o
C;after another
1 hour,it will increase 1
o
C again,and after 6hours,it will cease;after running for
1 hour under heating mode, the setting temperature will decrease 2
o
C, after another
1 hour,it will decrease the 2
o
C again,and after 3 hours,it will increase 1
o
C,and after
other 3 hours,it will cease.
(15) Manual defrosting function
Under heating(automatic heating)state,press continuously the SLEEP button on the
control unit for and times till heating 3 sounds from the buzzer, then the whole unit
will turn to the defrosting state.