Haier air conditioner Edition: 20070116
- 65-
6.4.2 Cooling suction pressure curves
HSU-09HSA03/R2(DB)
Cooling suction pressure table
Outdoor temp. (Humidity 46%) Indoor temp.
DB/WB
16ć 19ć 22ć
15ć
718 749 798
25ć
727 768 817
30ć
744 782 820
35ć
749 779 820
40ć
782 821 864
45ć
846 896 948
&22/,1*68&7,2135(6685(





ć ć ć ć ć ć
Outdoor Temp
DISCHARGE PRESSUR
E
ć
ć
ć