6.5 Sensible cooling value-temperature curves
HSU-09HSA03/R2(DB)
Sensible cooling value - Temperature table
Indoor temp. Outdoor temp. (Humidity 46%)
DB/WB
18ć 20ć 25ć 32ć 35ć 40ć 43ć 46ć
18/12ć 1885 1783 1720 1647 1489 1400 1315 1236
18/14ć 1917 1866 1800 1720 1545 1489 1400 1310
20/15ć 1982 1920 1845 1764 1634 1536 1408 1315
22/16ć 2061 1969 1935 1870 1691 1562 1445 1347
25/18ć 2137 2066 2003 1961 1774 1667 1491 1366
27/19ć 2232 2132 2063 2020 1885 1713 1570 1459
30/22ć 2320 2261 2192 2147 1941 1769 1630 1486
32/23ć 2430 2348 2260 2181 2051 1834 1699 1562
32/24ć 2501 2404 2302 2218 2056 1920 1723 1574