EasyManua.ls Logo

Haier HSU-24C13 HSU-22C13 - TROUBLESHOOTING; EEPROM Abnormality (Indoor Unit)

Haier HSU-24C13 HSU-22C13
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Air Conditioner
(9) Sleeping function
After setting the sleeping function, the refrigerating mode and dehumidification
mode will run as per the following rules:
6hours
T()
1 hour
Ts+2
Ts+1 1 hours
Ts
Sleep OFF t(hour)
As shown in the above diagram, after running for 1 hour under refrigerating mode
and dehumidification mode, the setting temperature will increase 1; after
another 1 hour, it will increase 1 again, and after 6 hours, it will cease.
(10). Abnormality diagnosing
For the abnormal phenomenon occurred, please conduct trouble analysis and troubleshooting
according to the following table: