Haier HSU-24H03/Z - Abnormality Diagnosing Table

Haier HSU-24H03/Z
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No Reason of trouble Phenomena Remarks
1 The sensor of indoor ambient
temperatureis in short circuit or
broken circuit
The compressor indictor
and
timing
indicator
extinguish,
and the
running indicator flickers
2 The temperature sensor of
indoor coil pipe is in short
circuit or broken circuit
The compressor indictor
and timing indicator are
on, and the running
indicator flickers
3 The indoor motoris damaged,or the
computer board is damaged
The power indicator and
running indicator of indoor
unit flicker twice, thepower
indicator, running indicator
and timing indicator flicker
togetherfor 1 second,then
repeating the cycle.
The motorhasno signal
feedback of Hall unit
For the abnormal phenomenon occurred, please conduct trouble analysis and troubleshooting
according to the following table:
48
Domestic Air Conditioner
Model: HSU-24H03/Z
Model: HSU-24C03/Z