HSU09VHJ˄DB˅-SM
Service Diagnosis
Domestic Air Conditioner
52
7.3.2
Indoor fan motor malfunction
Indoor Display

E14
Method of
The rotation speed detected by the Hall IC during fan motor operation is used to determine
Malfunction
abnormal fan motor operation
Detection
Malfunction
when the detected rotation feedback singal don’t receiced in 2 minutes
Decision
Conditions
Supposed Causes
Ƶ
Operation halt due to breaking of wire inside the fan motor .
Ƶ
Operation halt due to breaking of the fan motor lead wires
Ƶ
Detection error due to faulty indoor unit PCB
How to check Fan Motor (DC)
1. Check connector connection.
2. Check motor power supply voltage output (pins 1-4).
3. Check motor control voltage (pins 4-5).
4. Check rotation command voltage output (pins 4-6).
5. Check rotation pulse input (pins 4-7).
Notes:the a/c is electrifying,don’t pull out or insert the terminals of the
motor,else the motor would be damaged