8
1.Remove the packing material and packaging tape
Remove the all packing materials and packaging
tapes for transportation.
3. Placing conditions
A minimum of 10 cm space must be kept around
the refrigerator for ventilation and heat dissipation.
4. Adjust the leveling leg
Rotate the leveling legs with a wrench in clockwise
direction to extend them outward and support on
the ground. Make sure the refrigerator will not
move during operation.
•For safe transport, the bottom of the refrigerator is secured with a mounting plate.
Before installing the unit, the plate must be removed and placed under the unit.
•You may use a forklift and package carrier to unpack the unit. Use the bottom of the
unit for forklifting and such equipment to move the unit.
•During handling, the inclination angle of refrigerator shall not be greater than 45°.
Leveling legs
Downward
upward
Preparation before use
Caution
2.Inspect shipping accessories
Inspect the accessories inside the refrigerator
against the packing list. Contact Haier service
should there any discrepancy.
> 30cm from the top
>
1
0
c
m
f
r
o
m
t
h
e
b
a
c
k
> 10cm from
the left
> 10cm from
the right
33
Name Blood Bank Refrigerator
Model HXC-158 HXC-158B HXC-106
Exterior dimensions
(W x D x H) (mm)
560×570×1530 500×514×1055
Interior dimensions
(W x D x H) (mm)
460×370×950 430×350×830
Eff ective volume 158L 106L
Door Glass door with electric heat
Insulation CFC-Free foamed-in-place urethane
Compressor High Quality Hermetically sealed compressor
Shelves / Drawer 4 shelves / 4 baskets 4 Drawers 3 shelves / 4 baskets
Load Max:13.5kg per shelf Max:7.5kg per shelf
Refrigerating Method Forced convection cooling
Exterior / Interior Scratch resistant painted steel / Stainless steel
Condenser/Evaporater Fin tube type
Temperature Control Microprocessor controlled
Refrigerant R600a 80g R600a 80g R600a 75g
Interior light LED 3W
Net weight 107kg 113kg 49kg
Temperature range 4±1℃
Voltage 220-240V~/50Hz/60Hz
Rated power / current 320W/1.9A 320W/1.9A 253W/1.6A
Noise Level 42dB(A) 42dB(A) 41dB(A)
Foaming Agent HFO-1233zde
Climate Type ST ST N
Anti-shock Safety
Classifi cation
I
Power connection type Y
USB function / temperature
recorder
Optional / Optional Optional / Standard No
Alarm system
High-low temperature alarm, sensor error alarm, power failure alarm,
low battery alarm and door ajar alarm
Battery duration for alarm
system
48 hours (when battery is fully charged)
Rechargeable battery DC12V Rechargeable lead-acid battery
Note: Climate Type ST means the temperature is 18-38℃ ,Climate Type N means the temperature is
16-32
℃
.Due to continuous improvements, technical information on your refrigerator may be diff erent
from herein published.
Specifi cation • Packing List
Specifi cation