41
If the refrigerator is left unused in areas where supervision is unavailable for a long time, 
make sure children will not get close to the refrigerator and the door can not be completely 
closed. 
Do not place containers with water or heavy stuffs on the refrigerator. Personal injuries may 
be caused by falling articles and electrical leakage or shock may be caused by out flowed 
water due to deterioration of insulation. 
Do not ground the refrigerator through gas pipes, water supply pipes, telephone lines or 
lightning conductors. As electric shock or other dangers may be caused. 
Do not touch electrical parts such as power plug or switches with wet hands to prevent 
electric shock. 
Hold the power plug rather than the wire when pulling the plug from the socket. As electric 
shock or fire due to short circuit may be caused. 
Pull out the power plug when the refrigerator is under abnormal performance. As electric 
shock or fire may be caused. 
Users are not allowed to dismantle, repair or refit the refrigerator by themselves. As fire or 
personal injuries may be caused due to improper operation. 
Disconnect the refrigerator when repairs or maintenance are performed on the refrigerator 
to prevent electric shock or personal injuries. 
Make sure medicines or airborne particles inside or around the refrigerator will be not be 
inhaled during maintenance as health hazard may be caused. 
The refrigerator shall be used in safe regions when toxic, harmful or radioactive articles are 
stored inside. As improper use may pose danger to human health or environment. 
Pull out the power plug if the refrigerator is out of service for long time to prevent electric 
shock, leakage or fire caused by aging power lines. 
If the power line needs to be extended, the extended line shall be no smaller than 2mm² in 
sectional area and no longer than 3m in length. Otherwise, fire or electric shock may be 
caused. 
The power line for this refrigerator is provided with a standard three wire (grounding) plug, 
which complies with 16A. Do not remove or dismantle the grounding pin of power line in 
any case. Make sure the power plug is securely and reliably plugged into the socket to 
prevent fire. 
Apply socket with ground wire to prevent electric shock. 
If the socket fails to be grounded, ground wires must be installed by technician. 
Do not use the refrigerator outdoors. Electric leakage or shock may be caused if the 
refrigerator gets wet by rainwater. 
Do not place the refrigerator in humid places or places where the refrigerator may suffer 
splashing water. To prevent electric leakage or shock due to deterioration of insulation. 
Do not pour water on the refrigerator to prevent electric shock or short circuit. 
Apply the dedicated power supply marked on the nameplate of refrigerator to prevent fire 
or electric shock. 
If voltage below 198V or above 242V is applied, automatic voltage regulator above 4000W 
and appropriate for motor load shall be installed. 
Do not store inflammable, explosive or volatile articles inside the refrigerator and do not use 
flammable sprays nearby as explosion or fire may be caused. 
4
HXC-1308B
12 Drawers
HXC-1308
Blood Bank Refrigerator 
External dimensions (W X D X H) 
(mm) 
Internal dimensions (W X D X H) 
(mm) 
Effective volume 
Door 
Insulating materials 
Compressor 
Shelf / Drawer
Refrigeration mode 
Outer plate / inner plate 
Condenser / evaporator 
Refrigerant 
Headlamp 
Net weight 
Temperature of temperature 
measurement box 
Rated power supply 
Rated power / current 
Alarm system 
Rechargeable battery 
1440x925x1980 
1320x700x1500 
1308L 
Electrical heating glass door 
Hard polyurethane foam (fluorine-free) 
Totally enclosed imported compressor 
12 shelves / 48 baskets 
Forced Wind Cooling Circulation 
Spraying steel plate / stainless steel plate 
Fin / fin 
Computer control system 
R134a  490g  
LED   5W
310kg
4℃±1.5℃
220-240V~/50Hz
850W/4.2A
High-low temperature alarm, sensor fault alarm, power failure 
alarm,  low battery alarm and door opening alarm 
DC 12 V rechargeable battery 
Name 
Model 
Duration time of power failure alarm
48 hours (when battery is fully charged) 
I
Temperature controller 
USB function / temperature recorder  Standard / standard 
Y
Electric shock resistance type 
Power connect style
Climate Type
Foaming Agent
Noise Level
4
45dB(A)
CP/IP
Note: Climate Type 4 means the temperature is +30℃,the relative humidity is 55%.Technical 
information may vary from the appliance that you have just purchased due to technical improvements.
The loading of each shelf Max:30kg
Specification