Hamilton Safe Company
Step #3:
Remove the four screws that are now exposed from behind the door top channel. These may be twist off screws that
will require a chisel or punch to remove or drilled completely out.
Step #4:
The front panel will hinge down after the four top screws are removed. Cut or disconnect the wires connected to the
front panel. Then remove the screws holding the hinge and spring loaded roller and remove front panel.
Note
: Disconnect electric from night head before cutting or removing any wires.