EasyManua.ls Logo

Hamilton HA-1000 - Logic Wiring Detail; Customer Unit J7 Outputs Wiring; J5 Speaker Connections; J8 RJ45 Interconnect Wiring

Hamilton HA-1000
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RY_T9A-5
RY5
+12V_I
GND
P1
P2
S1
S2
S3
24V
T1
9
6
3
7
8
10
2
1
4
5
J2
6
3
2
1
4
5
J3
3
2
1
J13
5
2
3
1
4
J10
2
4
3
1
J9
2
3
1
4
J4
+12V_I
JP3
RY_THERM
1
1
3
3
2
2
J15
+12V_I
GND
RY_MONITOR
20A
ACC
JP1 JUMPER 1: MULTIPLE BOARD JUMPER. JUMPER "ON" FOR NORMAL
OPERATION WITH MANUAL TELLER UNIT. JUMPER "OFF" ONLY WHEN
USED IN DUAL CONTROL BOARD SYSTEMS.
JP2 JUMPER 2: REMOTE INPUT JUMPER. JUMPER "ON" FOR NORMAL
OPERATION WITH MANUAL TELLER UNIT. JUMPER "OFF" ONLY WHEN
USED IN DUAL CONTROL BOARD SYSTEMS.
JP3 JUMPER 3: DOOR MOTOR AUXILARY THERMAL PROTECTION JUMPER.
JUMPER "ON" FOR NORMAL OPERATION IN ALL UNITS EXCEPT HA33.
JUMPER "OFF" ONLY IF THE DOOR MOTOR HAS AUXILIARY
CONNECTIONS FOR THERMAL PROTECTION (HA33 ONLY).
GNDEARTH
EARTH
24_AC
24_AC_NEUT
1
1
3
3
2
2
J6
3A
NEUT
RY_AIR
24_AC_NEUT
24_AC
2
3
5
6
8
1
4
7
J8
RJ45JACK
5
2
4
3
6
1
J11
24
3
5
1
RY_T9A-5
RY6
4
5
3
8
1
7
6
2
-
+
RY9
C2C1
Power Switch
C2C1
Customer Send Switch
C2C1
Teller Call Button
C2
C3
C1
LS3
1
2
J12
24
3
5
1
C2
C3
C1
C2
C3
C1
24
1
3
-
+RY4
RY_T9A
4
5
3
8
1
7
6
2
-
+
RY10
5
2
6
3
4
7
1
J5
C2
C3
C1
LS2
24
1
3
-
+RY2
RY_T9A
24
1
3
-
+RY1
RY_T9A
8
5
2
7
4
3
6
1
9
J7
24
1
3
-
+RY3
RY_T9A
Vacuum
Pressure
24VAC POWER
MICROPHONE
SPEAKER
CABLE CONNECTIONS
MATRIX AUDIO
J5
1
7
4
3
6
2
5
SHLD
MC-
TC+
SP+
SP-
MC+
TC-
= DEFAULT SETTING
ON = MULTI-MOTOR / OFF = SINGLE MOTOR
ON = TIMING MODE / OFF = RUN MODE
ON = TELLER / OFF = CUSTOMER
NEUTRAL
60HZ
120VAC
Date :Drawing Number :
Rev - 1
Rev - 2
MODEL HA-1000 CUSTOMER UNIT
ELECTRICAL DIAGRAM
WITH I/O CONTROL E0873
1/22/0899-977
MC-
MC+
Off
SHLD
MC-
TC+
SP+
SP-
SP+
SW2
SW1
SW3
SHLD
On
MC+
SP-
TC-
Input 2
Input 5
Input 6
Input 9
Input 1
Input 3
E0873 Board
Input 4
Input 7
Input 8
Input 10
TURBINE MODE
BLOWER RUN TIME SET
UNIT SELECTION
Input 1: Door Open
Input 2: Door Close
Input 3: N/A
Input 4: N/A
Input 5: N/A
Input 6: Door Safety
Input 7: Call Button
Input 8: Send Button
Input 9: Optional auto door close
Input 10: N/A
J7-1: Pressure Motor
J7-2: Pressure Motor
J7-3: Close Customer Door
J7-4: Common for blower motors
J7-5: Common for blower motors
J7-6: Common for Door Motors
J7-7: Vacuum Motor
J7-8: Vacuum Motor
J7-9: Open Customer Door
Local Turbine
DOOR OPEN LIMIT SWITCH
DOOR CLOSE LIMIT SWITCH
BAR SWITCH
DOOR SAFETY
LS5
LS4
TS#1
TS#4
TS#5
TS#6
TS#4
TS#2
TS#3
TS#3
Customer Door
Capacitor
7.5mfd
RJ45 INTERCONNECT
RS485 B
RS485 A
Teller Send Button
Night Lock (input 5)
Teller Recall Button
Spare (input 10)
Comm line to remote board (+12V_I)
Teller Carrier Present (input 4)
JP2
JP1
JP3
Logic Wiring Detail

Other manuals for Hamilton HA-1000