HA1000 Interconnection Cable
CAT5 Interconnect Cable Wiring
The I/O control board system requires an interconnect cable to connect the manual teller unit to the
control board located in the customer unit and/or the control board located in the teller unit to the
control board located in the customer unit. This cable is a standard category 5 (CAT5) cable,
Hamilton part number E0889, and terminated with male RJ-45 connectors on both ends. The
connectors should be wired in the straight through design as shown below on both ends. There are
commercially available testers that can be used to verify correct connector installation and function.
Wire
Pin #
Teller Connections
White/Orange
1
Spare
Orange
2
Teller Nigh Lock
White/Green
3
Teller Carrier Arrival
Blue
4
Teller Recall
White/Blue
5
Door Closed / Teller Send
Green
6
Common
White/Brown
7
RS485 A
Brown
8
RS485 B