Customer Control Board Connections
TO AUDIO MATRIX
MICROPHONE SHIELD - 7
MICROPHONE POSITIVE (+) - 6
MICROPHONE NEGATIVE (-) - 5
TELLER CALL POSITIVE (+) - 4
TELLER CALL NEGATIVE (-) - 3
SPEAKER POSITIVE (+) - 2
SPEAKER NEGATIVE (-) - 1
J3
J2
J4
J4 INPUTS
DOOR AUTO-CLOSE - 1
COMMON - 2
SWITCHES
SWITCH 1
SWITCH 2
SWITCH 3
J13
MICROPHONE
CONNECTION
J12 - SPEAKER
CONNECTION
J8 - RJ45
INTERCONNECT
J7 OUTPUTS
NOT USED - 1
PRESSURE - 2
DOOR CLOSE - 3
NOT USED - 4
HOT, BLOWER MOTORS - 5
HOT, DOOR MOTOR - 6
NOT USED - 7
VACUUM - 8
DOOR OPEN - 9
POWER INPUT
24 VAC
CENTER TAP
24 VAC
J3 INPUTS
DOOR SAFETY (NC) - 1
COMMON - 2
TELLER CALL (NO) - 3
COMMON - 4
CUSTOMER SEND (NO) - 5
COMMON - 6
AUDIO
RY4
J15
J11
J6
RY6
J7
RY2 RY1
J4
J2
C1
J8
RY3
J13
BR1
J3
J12
JP1
C9
4
6
4
1
AC - CT - AC
OFF
5
6
2
3
Inputs 3-12
J7 Pin 6 - Common for relays 3 and 4
J9
J10
BR3
C15
TVS1
TVS10
J14
C3
C14
BR2
TVS9
L1
C17
RY5
C2
C5
TVS8
D9
C4
Lane Stat
Teller Send
Carrier Present
Teller Recall
Door Open
Door Closed
Link
Door Safety
Night lock
Remote Carrier
Spare
(Option)
Air Flow
T/R Call
Vid. Power
Send
Spare/Teller
Auto Close
Carrier
Recall
Vacuum
Outputs
Pressure
Closing
Opening
Outputs
Mute
Sw2 Sw1Sw3
Data Rec.
Mic
Inputs
Teller
Call
Inputs Inputs
Power
Firmware Version
E0873-C
E0873-T
1
2
3 9
7
8
SW4
JP3
SW3 - On = Teller Board
SW2 - Optional run mode
SW4 - Carrier Recall
SW1 - Carrier Time Set
D8
D7
J2 INPUTS
DOOR OPEN SWITCH (NO) - 1
COMMON - 2
DOOR CLOSE SWITCH (NO) - 3
COMMON - 4
J14 OUTPUTS
1 - 12VDC +
2 - 12VDC -

Other manuals for Hamilton HA-1000