EasyManua.ls Logo

Handicare 2000 SIMPLICITY - Page 48

Handicare 2000 SIMPLICITY
364 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
48 HANDICARE 2000 SIMPLICITY / STYLE INSTALLATION MANUAL
Appendix 2
Code: Meaning:
d Relay not open (stopped)
Description:
The main power relay is welded closed.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
Code: Meaning:
F
F Brake semi-conductor failed
Description:
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
Code: Meaning:
g Brake not connected
Description:
Telephone fault finding action:
Send engineer.
On site fault finding action:
Check brake.
Code: Meaning:
H
H Relay not open (Pre delay)
Description:
The main power relay is closed early.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
Code: Meaning:
n Half speed
Description:
Telephone fault finding action:
Send engineer if permanently showing.
On site fault finding action:
Check reed switches and dipswitch settings.
Check battery voltage.
Code: Meaning:
L
L Current limit exceeded
Description:
Telephone fault finding action:
Check client understands loading limits.
Send engineer if persistent fault.
On site fault finding action:
Check motor and track for obstructions.
Code: Meaning:
E
E Relay not closed
Description:
The main power relay did not close.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Check battery voltage and replace if necessary,
otherwise replace main board.
Code: Meaning:
L
J Hinge interlock switch error
Description:
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace hinge interlock roller switch.