OPERATION
MANUAL
Inverter CO
2
/MAG Gas Shielded
Welding Machine
NBC-250D/350M
Attention:
For your safety, please only allow technicians to operate, maintain
and repair this machine.
You are advised to read this operation manual thoroughly before
operating the machine. Please keep this manual for future reference
and safety information.

Questions and Answers

  • K
    Kevin SandersAug 13, 2025
    What to do if the Hanshen NBC-250D ampere meter displays E01 when welding?
    • C
      Curtis HoAug 13, 2025
      If your Hanshen Welding System displays 'E01' on the ampere meter during welding, it indicates a prolonged overload. To resolve this, adhere to the welding machine's duty cycle guidelines during operation.
  • M
    Micheal HillAug 17, 2025
    Why won’t the heating pressure reducing flow meter heat up on my Hanshen NBC-250D Welding System?
    • S
      Scott OlsenAug 17, 2025
      If the heating pressure reducing flow meter of your Hanshen Welding System won’t heat up, the possible causes are a broken meter (in which case you should replace it), a short circuit (you should fix the heating cable), a broken fuse (you should change the 8A fuse), or no output from the welder (you should check if there is output from welder).
  • T
    Tracy OwenAug 20, 2025
    Why can't I adjust the welding current on my Hanshen NBC-250D?
    • J
      johnriveraAug 21, 2025
      If you cannot adjust the welding current on your Hanshen Welding System, the issue might be with a broken wire feeder control cable or damaged control PCB (you may need to change the wire feeder control cable or PCB), a broken connection wire of the current divider (you may need to reconnect the lines), or a broken control panel of the welder (you may need to change the control panel).
  • M
    Michael RossAug 25, 2025
    Why does the air switch shut off when I turn on the Hanshen NBC-250D Welding System?
    • T
      Theresa WagnerAug 26, 2025
      If the power switch trips immediately after turning on your Hanshen Welding System, it could be due to a broken air switch (you should change the air switch), a broken IGBT (you should change the IGBT), a broken 3-phase commutate bridge (you should change the 3-phase commutate bridge), or a broken controlling panel (you should change the controlling panel).
  • L
    Laura FaulknerAug 28, 2025
    What to do if wire feeding is normal, but there is no gas flow when pressing the torch switch on my Hanshen NBC-250D?
    • J
      Jennifer MiddletonAug 28, 2025
      If pressing the torch switch on your Hanshen Welding System results in normal wire feeding but no gas flow, this could be due to a broken control motherboard of the welder (you should change the control motherboard) or a broken electromagnetic valve (you should change the electromagnetic valve).
  • J
    Julia WadeSep 1, 2025
    How to fix the indicator light if it's not on after switching on the Hanshen NBC-250D Welding System?
    • K
      Kenneth HernandezSep 1, 2025
      If the indicator light on your Hanshen Welding System is not on after switching on the power, it could be due to damage to the air switch on the back panel (you should change the air switch) or a broken fuse (you should change the fuse).
  • R
    Randy ThompsonSep 5, 2025
    What to do if the wire-feeder doesn't work and there is no open-circuit voltage when pressing the torch switch on my Hanshen Welding System?
    • R
      Richard MoranSep 5, 2025
      If pressing the torch switch on your Hanshen Welding System results in the wire-feeder not working and there's no open-circuit voltage, the torch switch might be broken (you should change the torch) or the control cable of the wire-feeder might be broken (you should fix the control cable of wire-feeder).
  • B
    Brian HillSep 8, 2025
    Why is there an unstable arc and big splash when using my Hanshen NBC-250D Welding System?
    • D
      Donald Turner Jr.Sep 8, 2025
      If you're experiencing an unstable arc and big splash with your Hanshen Welding System, it could be due to an incorrect procedure (you should correct the procedure) or a badly worn nozzle (you should change the nozzle).

Summary

1. CHARACTERISTICS

2. SAFETY INFORMATION

2.1 Fatal Accident Prevention

Ensure correct voltage, comply with laws, wear safety gear, maintain ventilation, and avoid opening the welder's shell.

2.2 Fire and Burn Prevention

Keep welder away from inflammables, sparks, and combustion gas sources. Secure installation if needed.

2.3 Connection and Usage Safety

Disconnect power before gas connection, avoid wet gloves, use correct cables, and ensure proper earthing.

6. OPERATION

6.1 Initial Preparation

Steps include powering on, selecting wire/nozzle, manual wire feeding, and performing a gas test.

6.2.1 Spot and Short Seam Welding

Procedure for spot/short seam welds: set end arc OFF, adjust current/voltage, and use torch switch.

6.2.2 Long Weld Seam Welding

Procedure for long welds: set end arc ON, adjust current/voltage, use torch switch for arc start/stop and crater filling.

7. DAILY MAINTENANCE AND TROUBLE SHOOTING

7.1 Maintenance Precautions

Ensure secure connections, avoid short circuits, maintain ventilation, and perform regular internal part checks and cleaning.

7.2 Troubleshooting Common Issues

Guide to diagnosing and resolving common problems like indicator lights, air switch tripping, and unstable arc.

7.3 Post-Diagnosis Solutions

Provides solutions for specific faults such as broken fuses, PCB issues, and other detected problems.