Loading...
[AK5352]
/1
-
PIN/FUNCTION
No. Pin Name I/O FUNCTION
1 AINR+ I Right channel analog positive input pin
2 AINR- I Right channel analog negative input pin
3 VREF O Voltage Reference output pin (VA-2.6V)
Normally connected to VA with a 0.1uF ceramic capacitor in
parallel with a 10uF electrolytic capacitor.
4 VA - Analog section Analog Power Supply, +5V
5 AGND - Analog section Analog Ground
6 AINL+ I Left channel analog positive input pin
7 AINL- I Left channel analog negative input pin
8
10
11
14
TST1
TST2
TST3
TST4
Test pin (Pull-down pin)
Should be left floating.
9 HPFE I High Pass Filter Enable pin (Pull-up pin)
"H": ON
"L": OFF
12 VD - Digital section Digital Power Supply pin, +5V
13 DGND - Digital section Digital Ground pin
16 PD I Power Down pin
"L" brings the device into power-down mode. Must be done
once after power-on.
17 MCLK I Master Clock input pin
CMODE="H" : 384fs
CMODE="L" : 256fs
18 SCLK I/O Serial Data Clock pin
Data is clocked out at the falling edge of SCLK.
Slave mode: 64fs clock is input usually.
Master mode: SCLK outputs a 64fs clock.
SCLK stays low during the power-down mode(PD="L").
19 LRCK I/O L/R Channel Clock Select pin
Slave mode: An fs clock is fed to this LRCK pin.
Master mode: LRCK output an fs clock.
LRCK goes "H" at SMODE2="L" and "L" at SMODE2="H"
during reset when SMODE1 "H".
20 FSYNC I/O Frame Synchronization Signal pin
Slave mode: When "H", data bits are clocked out on SDATA.
As I
2
S slave mode ignores FSYNC, it should hold "L" or
"H".
Master mode: FSYNC outputs 2fs clock.
Stay low during the power-down mode(PD="L").