Harman Kardon FL8400 - Leakage Test

Harman Kardon FL8400
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FL8400
LEAKAGE
TEST
Before
returning
the
unit
to
the
user,
perform
the
following
safety
checks:
1.
Inspect
all
lead
dress
to
makes
certain
that
leads
are
not
pinched
or
that
hardware
is
not
lodged
between
the
chassis
and
other
metallic
parts
in
the
unit.
2.
Be
sure
that
any
protective
devices
such
as
nonmetallic
control
knobs,
insulating
fishpapers,
cabinet
backs,
adjustment
and
compartmént
covers
or
shields,
isolation
resistor-capacity
networks,
mechanical
insulators,
etc.
Which
were
removed
for
servicing
are
properly
reinstalled.
3.
Be
sure
that
no
shock
hazard
exists;
check
for
leakage
current
using
Simpson
Model
229
Leakage
Tester,
standard
equipment
item
no.
21641,
RCA
model
WT540A
or
use
alternate
method
as
follows:
plug
the
power
cord
directly
into
a
120-volt
AC
receptacle
(do
not
use
an
Isolation
transformer
for
this
test).
Using
two
clip
leads,
connects
a
1500
ohm,
10-watt
resistor
paralleled
by
a
0.15uF
capacitor,
in
series
with
all
exposed
metal
cabinet
parts
and
a
known
earth
ground,
such
as
a
water
pipe
or
conduit.
Use
a
VTVM
or
VOM
with
1000
ohms
per
volt,
or
higher
sensitivity
to
measure
the
AC
voltage
drop
across
the
resistor.
(see
diagram)
Move
the
resistor
connection
to
each
exposed
metal
part
having
a
return
path
to
the
chassis
(antenna,
metal
cabinet,
screw
heads,
knobs
and
control
shafts,
escutcheon,
etc.)
and
measure
the
AC
voltage
drop
across
the
resistor.
(This
test
should
be
performed
with
the
power
switch
in
both
the
on
and
off
positions.)
A
reading
of
0.35
volt
RMS
or
more
is
excessive
and
indicates
a
potential
shock
hazard
which
must
be
corrected
before
returning
the unit
to
the
owner.
VOLTAGE
OR
+
LEAD
TO
EXPOSED
METALIC
PARTS
SIMPSON
MODEL
229
ETC.
FOR
LEAKAGE
TEST
TO
EACH
EXPOSED
TO
AC
GROUND
SUCH
METAL
SURFACE
OF
“=
)
}=———
AS
WATER
PIPE
BX
CABLE
UNITUNDER
Test
=
HIGH
GROUND
CONDUIT
ETC.
LEAD
AC
SCALE
G
0,15uF
TEST
PROBE
CONNECT
TO
KNOWN
EARTH
GROUND