13
XXV Pellet Stove
This method can be done with or without a ue 
liner. Without a liner, the damper area must be sealed 
off with a steel plate. Kaowool, mineral wool or an 
equivalent non-combustible insulation is recommend-
ed on top of the steel plate to minimize condensation. 
In this method a cap should also be installed on the 
chimney to keep out rain.
Some places in the US and Canada require that 
the  vent  pipe  extend  all  the  way  to  the  top  of  the 
chimney. Per ULC S628.
Be sure to use approved  pellet vent pipe ttings. 
Seal  pipe  joints  with  silicone  or  aluminum  tape  in 
addition  to  the  sealing  system  used  by the manu-
facturer. Pipe size should be increased to 4" using 
this method. 
 
This method provides excellent venting for normal 
operation.  This method also provides natural draft 
in the event of a power failure. 
In this method a 4 inch liner is installed the entire 
length of the ue. Whether using a rigid or exible 
liner, a cap should be installed on the chimney to 
keep out rain. 
Fig. 14
Fig. 15