Check that all parts are present before installing. Contact Harrick Scientific for missing or damaged items.
Contact the Technical Support Center for additional information via phone or email (techsupport@harricksci.com).
Send comments and suggestions to Harrick Scientific Products, Inc. at their Pleasantville, NY address.
Overview of the ATC's capabilities for manual or computer-controlled temperature profiling and its dual thermocouple inputs.
The ATC is designed for use in light industrial and laboratory environments only.
Familiarize yourself with the controller's front panel and connections before operation.
Instructions for connecting the temperature controller to the accessory, including checking switches and plugging in the line cord.
Procedure to set the thermocouple type, defaulting to K-type (H) for most Harrick accessories.
Procedure to set the control type, typically 'Cntl' for single loop operation.
Procedure to select temperature units, choosing between Fahrenheit (F) or Centigrade (C).
Procedure to set the low temperature limit for TC1, typically to -200°C.
Procedure to set the high temperature limit for TC1, typically 750°C or 1000°C for specific chambers.
Procedure to set the low power limit for the heater, typically to 0%.
Procedure to set the high power limit, typically 35% or 75%, based on the desired temperature range.
Procedure to set the auto-tune set point percentage, typically to 90%.
Procedure for auto-tuning the controller when the accessory or set point is changed. Takes approximately 5 minutes.
After auto-tuning, ensure the accessory is at room temperature before activating the heater switch.
Procedure to set thermocouple types (In1 and In2) for accessories using two thermocouples.
Procedure to set control type for cascade or double loop regulation, e.g., 'CSCd' or 'CSAC'.
Procedure to select temperature units, choosing between Fahrenheit (F) or Centigrade (C).
Procedure to set low temperature limits for TC1 and TC2, typically to -200°C.
Procedure to set high temperature limits for TC1 and TC2, typically to 750°C.
Procedure to set the low power limit, typically to 0%.
Procedure to set the high power limit, typically 35% or 75%, based on the desired temperature range.
Procedure to set the auto-tune set point percentage, typically to 90%.
Procedure for auto-tuning the controller when the accessory or set point is changed. Takes approximately 5 minutes.
After auto-tuning, ensure the accessory is at room temperature before activating the heater switch.
Instructions on how to replace fuses, including referring to tables for correct fuse types and positions.
Guidance on troubleshooting issues like the front panel not lighting up or the ATC failing to heat.