Maintenance 1B20, 1B27, 1B30, 1B40, 1B50
58
HATZ
Operator's Manual
Symbol Maintenance in-
terval
Maintenance activity/check Chapter
Every 8–15 oper-
ating hours or ev-
ery day before
starting
Check the oil level. 7.6 Checking the
oil level and
adding oil if nec-
essary, page 47
Check the engine oil level in
the bottom section of the oil
bath filter and examine the oil
for contamination. Change the
oil if it is sludgy.
7.6.2 Oil level in
the oil bath filter
(option), page 49
In models with a cyclone pre-
cleaner: remove the dust trap.
8.2.12 Maintain-
ing the dry air fil-
ter, page 83
Check the intake area of the
combustion and cooling air.
8.2.3 Checking
the intake area,
page 59
Check the air filter mainte-
nance indicator.
7.9 Check the air
filter warning indi-
cator (option),
page 54
Weekly Check the water separator. 7.8 Checking the
water separator,
page 52
250h
Every 250 operat-
ing hours
Maintain the oil bath filter. 8.2.7 Maintaining
the oil bath filter,
page 68
Change the engine oil. 8.2.4 Change the
engine oil, page
60
Check and set the tappet
clearance.
8.2.6 Check and
set the tappet
clearance, page
65
Clean the cooling air area. 8.2.8 Clean the
cooling air area,
page 70
Check the screw connections. 8.2.9 Check the
screw connec-
tions, page 73
Clean the exhaust screen. 8.2.10 Clean the
exhaust screen,
page 73

Table of Contents