89
4000715370
E 06.18 - V2
USA / GB
HA20RTJ - HA20RTJ O - HA20RTJ PRO - HA61RTJ O - HA61RTJ PRO
C
- Pre-operation inspection
4.2 - ACTIVATION OF CONTROLS
The deadman foot pedal (enable switch) must be activated to allow any movement.
The "Enable Switch" system depends on the machine configuration and will consist of one of
the following :
• Joystick trigger at platform box (if fitted).
• Foot pedal (enable switch) in the platform.
• Enable switch button at ground box.
4.3 - FAULT DETECTOR
The machine is equipped with an on-board fault detection system, which indicates the type of
fault to the operator.
The fault is identified by a default code.
The default code is displayed at the ground control box.
According to the type of fault, the machine MAY switch into DOWNGRADEMODE mode and
certain movements are prevented to maintain Operator's safety.
Do not use the machine until the fault has been corrected.
4.3.1 - Indicators/LED's test
From the ground control box
From the platform control box
Step Action
1 Pull the E-Stop button ( 46 ) at the platform control box.
2
Set the key switch ( 22 ) at ground box to the position
3 Check that the indicators ( 10, 13, 15, 19 ) and ACTIV'SCREEN (23) are lit.
4 Check that the LED's on the display are all turned off after 1 sec.
Step Action
1 Pull E-Stop button ( 9 ) at ground box.
2
Set the key switch ( 22 ) at ground box to the position
3 First push in the E-Stop button ( 46 ) at platform box, then pull out.
4 Check that the LED's ( 101 - 117 ) light up on the platform display panel.
5 Check that the LED's ( 101 - 117 ) on the display are all turned off after 1 sec.