103 4000662720 E 06.17 USA / EN
C
- Study of the electric schematics
HA26 RTJ O - HA26 RTJ O SW - HA26 RTJ PRO - HA26 RTJ PRO SW - HA80 RTJ O - HA80 RTJ PRO
2.5.8 - Telescope
2.5.8.1 - Validation
REQUIREMENTS DEFINITION
BTV03
Extension (O:out) or retraction (I:in) of boom's telescope is inhibited if at least one of the following cut-off
conditions is active :
CUT-OFF O I GENERAL CUT-OFF CONDITIONS
1 General
1 1 1 Generator is running
2 1 1 Maximum number of running movements is reached
3 1 1 Safety valves tool is active
411
Upper controls emergency stop pushed and
overriding mode not active
511
Delay to change fuel selection (dual fuel engines
only)
REQUIREMENTS DEFINITION
BTV03
CUT-OFF O I
SIMULTANEOUS MOVEMENTS CUT-OFF
CONDITIONS
2
Simultaneous
movements
1..10 1 1
Requirements SM_CE_03 | SM_AU_02 |
SM_ANSI_02
REQUIREMENTS DEFINITION
BTV03
CUT-OFF O I OVERLOAD CUT-OFF CONDITIONS
3 Overload
111
Overload alarm is active and not overriding
control box
21N/A
Overload alarm is active and machine in
position "P5"
REQUIREMENTS DEFINITION
BTV03
CUT-OFF O I TILT CUT-OFF CONDITIONS
4 Tilt 1 1 N/A
Tilt active and option "movements restriction under
tilt conditions" is active and machine is unfolded
REQUIREMENTS DEFINITION
BTV03
CUT-OFF O I REACH LIMIT CUT-OFF CONDITIONS
5 Reach limit 1 1 N/A
Machine in position "P5" and 350kg/770lbs
applied load