108 4000662720 E 06.17 USA / EN
HA26 RTJ O - HA26 RTJ O SW - HA26 RTJ PRO - HA26 RTJ PRO SW - HA80 RTJ O - HA80 RTJ PRO
C
- Study of the electric schematics
2.5.9.2 - Actuators
REQUIREMENTS DEFINITION
JMV04
Following limits are applied on the set point (SETP[Jib]) if engine is running (CTRL[Engine] = RUNNING)
:
LIMITATION VALUE (%) LIMITATION CONDITION :
AVAILABLE ONLY WHEN ENGINE IS RUNNING
(CTRL[Engine] = RUNNING)
U D
1 80 80 Turret control box is active
2 70 70 Overriding control box is active
3 65 65 Tilt active
4 65 65 System failures : Load management, oscillating axle, brake release
Lower value is applied if several limits are active ( 100% = max speed) -No slow down with emergency
pump
REQUIREMENTS DEFINITION
JMA01
The following components drive the drive movement :
• YV900: Control movement speed.
• YV620U/YV620D: Control movement direction.