3 - Failures list
• For any type A (ACTIVE) failure code, it will appear on display in lower control and the warning light will flicker
on upper controls (see below).
• For any type D (DETECTED) failure code, it will also appear on display in lower control and the warning light
will flicker on upper controls.
• For any type N failure code, it means that this alarm will never appear on display.
• An internal code (column C) with 5 digits, visible only on the console, allows specifying the trigger conditions of
the failure.
Each trigger condition is associated with a single code number (16 possible single codes in decimal format
corresponding to a single bit in binary format) :
• If several conditions are active at the same time, single codes are added to form the resulting code displayed.
For example, il conditions 1 and 4 of single code are active, then the resulting code displayed will be 5 (1+4=5).