133 4000662720 E 06.17 USA / EN
E
- Adjustments
HA26 RTJ O - HA26 RTJ O SW - HA26 RTJ PRO - HA26 RTJ PRO SW - HA80 RTJ O - HA80 RTJ PRO
3.1 - LIST OF FAILURES PER CATEGORY
FAILURES N DEC DESCRIPTION
CONTACTORS
F02.02
Emergency
Pump Contactor
KM120
D
Digital output's failure : Emergency pump relay
--> KM120=FAIL
• Check relay
• Check connection to ground
• Check connection to U106 ECU
F02.04
Power Contactor
KMP
D
Incoherence between the emergency stop status and the presence of voltage on power line
--> =0 & (12VD1>8.00V | 12VD2>8.00V | 12VD3>8.00V | 12VD4>8.00V | 12VD5>8.00V |
12VF1>8.00V | 12VF2>8.00V | 12VF3>8.00V | 12VF4>8.00V)
• Check emergency stops
• Check relay KMP
• Check fuses
• Check wiring
F02.05
Heating Relay
KM160
D
Digital output's failure : Preheating relay and engine is not Tier IV
--> KM160=FAIL & CFG[Engine]=TierIII
• Check relay
• Check connection to ground
• Check connection to U106 ECU
FAILURES N DEC DESCRIPTION
RELAYS
F03.06
Horn Relay
KA9
D
Digital output's failure : Horn relay
--> KA9=FAIL
• Check relay
• Check connection to ground
• Check connection to U106 ECU
F03.07
Relay Failure
KA6
D
Relay failure : KA6 not controlled to active state and power is ON
--> KA6 relay is stuck
• Check relay
• Check connection to ground
• Check connection to U107 ECU
F03.08
Start Relay
KA4
D
Digital output's failure : Starter relay
--> KA4=FAIL
• Check relay
• Check connection to ground
• Check connection to U106 ECU
F03.09
Supply/
KeySwitch Rel
KA3
D
Digital output's failure : Engine supply relay
--> KA3=FAIL
• Check relay
• Check connection to ground
• Check connection to U106 ECU
F03.11
Generator Relay
KA2
D
Digital output's failure : Generator relay failure while generator on (And failure is not low current)
--> =FAIL & SETP[Generator] = ON
• Check relay
• Check connection to ground
• Check connection to U106 ECU
F03.13
Fuel/Gazoline
relay
KA140
D
Digital output's failure : Fuel selector relay
--> KA140=FAIL & CFG[Engine] = WG2503-GL
• Check relay
• Check connection to ground
• Check connection to U106 ECU