167 4000662720 E 06.17 USA / EN
F
- Simplified breakdown guide
HA26 RTJ O - HA26 RTJ O SW - HA26 RTJ PRO - HA26 RTJ PRO SW - HA80 RTJ O - HA80 RTJ PRO
6 - No movement
• Machine in overload above 3 meters (load cells SP800/SP801) or wrong calibration.
• Platform in slope/tilt above 3 meters ( SQ800: not for US).
• Load sensing valve YV800.
• Enable touch pad (low control box SA905EN).
• Foot switch pedal SB800 (upper controls only).
• ECU modules (SPU7066/Node B2 basket).
• Drive joystick SM902 off neutral and/or signal out of range.
• No LS pressure LS (20 bars) or equipment pump ( 240bars).
7 - No boom
• Touch pad SA520 U/D.
• Joystick SM900 off neutral and/or signal out of range.
• Valves YV802/YV520U/D.
• Machine in outreach limitation (SQ521/SQ522/SQ523/SQ524/SQ530/SQ531/SQ532/SQ533).
• Machine in overload above 3 meters or wrong calibration.
• ECU modules (SPU/Node B2 basket).
• No pressure.
8 - No telescopic boom
• Touch pad SA530I/O.
• Joystick SM901 off neutral and/or signal out of range.
• Valves YV801/YV530/YV530O/I.
• Machine in outreach limitation (SQ521/SQ523/SQ530/SQ531/SQ532/SQ533).
• Machine in overload above 3 meters or wrong calibration.
• ECU modules (SPU/Node B2 basket).
• Flow control valve.
• No pressure.
9 - No turret rotation
• Touch pad SA250L/R.
• Joystick SM900 off neutral and/or signal out of range.
• Valves YV250/YV250L/R.
• ECU modules (SPU/Node B2 basket).
• Flow control valve.
• No pressure.