EasyManua.ls Logo

Haulotte HA26 RTJ PRO SW - Drive; Validation

Haulotte HA26 RTJ PRO SW
273 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
90 4000662720 E 06.17 USA / EN
HA26 RTJ O - HA26 RTJ O SW - HA26 RTJ PRO - HA26 RTJ PRO SW - HA80 RTJ O - HA80 RTJ PRO
C
- Study of the electric schematics
2.5.3 - Drive
2.5.3.1 - Validation
REQUIREMENTS DEFINITION
DSV03
Forward (F) and/or reverse (R) drive motion is/are inhibited if at least one of the all cut-off condition is
activated :
CUT-OFF F R GENERAL CUT-OFF CONDITIONS
1 General
1 1 1 Generator is running
2 1 1 Maximum number of running movements is reached
3 1 1 Safety valves tool is active
4 1 1 Upper emergency stop pushed
511
Delay to change fuel selection (dual fuel engines
only)
REQUIREMENTS DEFINITION
DSV03
CUT-OFF F R
SIMULTANEOUS MOVEMENTS CUT-OFF
CONDITIONS
2
Simultaneous
movements
1..10 1 1
Requirements SM_CE_03 | SM_AU_02 |
SM_ANSI_02
REQUIREMENTS DEFINITION
DSV03
CUT-OFF F R OVERLOAD CUT-OFF CONDITIONS
3 Overload 1 1 1 Overload alarm is active
REQUIREMENTS DEFINITION
DSV03
CUT-OFF F R TILT CUT-OFF CONDITIONS
4 Tilt 1 1 1 Tilt activated with unfolded machine
REQUIREMENTS DEFINITION
DSV03
CUT-OFF F R REACH LIMIT CUT-OFF CONDITIONS
5 Reach limit N/A N/A N/A N/A