97 4000662720 E 06.17 USA / EN
C
- Study of the electric schematics
HA26 RTJ O - HA26 RTJ O SW - HA26 RTJ PRO - HA26 RTJ PRO SW - HA80 RTJ O - HA80 RTJ PRO
2.5.6 - Arm
2.5.6.1 - Validation
REQUIREMENTS DEFINITION
AMV03
Raise (U:Up) and/or descent (D:Down) of arm is/are inhibited if at least one of the all cut-off condition is
activated (from general to specific) :
CUT-OFF U D GENERAL CUT-OFF CONDITIONS
1 General
1 1 1 Generator is running
2 1 1 Maximum number of running movements is reached
3 1 1 Safety valves ON tool is inactive
411
Upper controls emergency stop pushed and
overriding mode not active
511
Delay to change fuel selection (dual fuel engines
only)
REQUIREMENTS DEFINITION
AMV03
CUT-OFF U D
SIMULTANEOUS MOVEMENTS CUT-OFF
CONDITIONS
2
Simultaneous
movements
1..8 1 1
Requirements SM_CE_03 | SM_AU_02 |
SM_ANSI_02
REQUIREMENTS DEFINITION
AMV03
CUT-OFF U D OVERLOAD CUT-OFF CONDITIONS
3 Overload 1 1 1
Overload alarm is active and overriding control box
is inactive
REQUIREMENTS DEFINITION
AMV03
CUT-OFF U D TILT CUT-OFF CONDITIONS
4 Tilt
11N/A
Tilt active and option "movements restriction under
tilt conditions" is active and machine is unfolded
2N/A1
Tilt active and option "movements restriction under
tilt conditions" is active and machine in P4 position
(dual load machines only)
3N/A1
Tilt active and option "movements restriction under
tilt conditions" is active and machine in P5 position
(dual load machines only)
REQUIREMENTS DEFINITION
AMV03
CUT-OFF U D REACH LIMIT CUT-OFF CONDITIONS
5 Reach limit N/A N/A N/A N/A