Seite | Page 29
ATRIUM
®
HS 330 – Rehau Geneo | 500656
28.12
28.12
8.1
8.1
28.12
0
0
0
Ø 8
0
Ø 8
28.12
2
1
9.13
8.1
Use of the jig for threshold
Use stop tabs to always position the drilling jig flush to the
surface of the outer edges of the threshold with the sealing and
the end caps 9.12 fitted.
– Fix the drilling jig 28.12 in place on the threshold. Insert the
fixing bars of the drilling jig into the grooves of the threshold
and tighten the jig firmly. On every side, drill 6 holes of Ø 5.5
all the way through. By adjusting the stop tabs, the drilling jig
can be used left and right.
Endcaps threshold
– (1) Insert end cap 9.12 with sealing 9.10 into the threshold
and
– (2) Screw it in place tightly with 3 pan head 6.3 x 15 screws
9.13.
Repeat these steps on the other side of the threshold.
Fig.: ThermoTop
®
2.1 (ThermoTop
®
comfort accordingly)
Fig.: ThermoTop
®
(ThermoTop
®
comfort accordingly)
Montage Bodenschwelle | Mounting threshold
Anwendung der Bohrlehre Bodenschwelle
Use of the jig for threshold
Fixiersteg
Fixing bar
Anschlag
Stop
Anschlag
Stop
Anwendung der Bohrlehre Bodenschwelle
Die Bohrlehre mittels Anschlaglaschen immer flächenbündig zu
den Außenkanten der Bodenschwelle mit montierten Dichtungen
und Endkappen 9.12 anlegen.
– Bohrlehre 28.12 an Schwelle fixieren. Die Fixierstege der
Bohrlehre in die Nuten der Bodenschwelle einstecken und die
Lehre fest spannen. An jeder Seite 6 Löcher mit Ø 5,5 durch-
gehend bohren. Durch Verstellung der Anschlaglaschen ist die
Bohrlehre links und rechts verwendbar.
Endkappen Bodenschwelle
– (1) Endkappe 9.12 mit Dichtung 9.10 in Bodenschwelle
einstecken und
– (2) mit 3 Euroschrauben Pan-Head 6,3 x 15 9.13
festschrauben.
Diese Arbeitsschritte auf der anderen Seite der Bodenschwelle
wiederholen.
Abb.: ThermoTop
®
2.1 (ThermoTop
®
comfort entsprechend)
Abb.: ThermoTop
®
(ThermoTop
®
comfort entsprechend)