Seite | Page 62
ATRIUM
®
HS 330 – Rehau Geneo | 500656
4 x AMO III
Ø 7,5 x 102
3.2
3.1
9.17
5
1
1
2.2
2.1
9.17
9.19
9.19
9.17
Installation of the threshold,
assembly of profiles and fixed sash
Fig. 7
– (1) Use silicone to seal the corner area of fixed sash/jamb and
support profile.
– (2) Put the frame profiles onto the corner connections.
– (3) Screw the threshold with frame profiles in place through the
packers for threshold 9.17 using (customer-provided) AMO
III Ø 7,5 x 102 screws. In the following order: Exterior (3.1),
interior (3.2), centre (3.3); see Detail “View from below”.
– (4) Seal the screw heads with silicone.
– (5) Use (customer-provided) screws Ø 6 x 110 to screw the fixed
glass panel to the threshold.
Fig.: ThermoTop
®
(ThermoTop
®
comfort accordingly)
Einbau Bodenschwelle | Installing Threshold
Rehau Geneo | Rehau Geneo
Einbau Bodenschwelle, Zusammenbau Profile und Festflügel
Installation of the threshold, assembly of profiles and fixed sash
Abb. 7 | Fig. 7
Abb.: ThermoTop
®
(ThermoTop
®
comfort entsprechend)
Ansicht von unten
View from bottom
Einbau Bodenschwelle,
Zusammenbau Profile und Festflügel
Abb. 7
– (1) Den Eckbereich Festflügel/Zarge und Aufbauprofil mit
Silikon abdichten.
– (2) Rahmenprofile auf Eckverbinder setzen.
– (3) Bodenschwelle mit Rahmenprofilen durch Unterlegplatten
Bodenschwelle (9.17) mit Schrauben AMO III Ø 7,5 x 102
(bauseits) verschrauben. In der Reihenfolge: Außenseite
(3.1), Innenseite (3.2); siehe Detail ‚Ansicht von unten‘.
– (4) Schraubenköpfe mit Silikon abdichten.
– (5) Festfeld mit Schrauben Ø 6 x 110 (bauseits) an der
Bodenschwelle anschrauben.