I N D O O R A I R Q U A L I T Y
HCWB3
Healthy Climate
®
By-Pass Humidier
Bulletin No. 210543
September 2009
Model Number Identification
HCWB 3 - 17 A
Unit Type
HCWB = Healthy Climate By-Pass Humidier
Nominal Capacity
12 = 12 US Gallons per day
17 = 17 US Gallons per day
Features
WARRANTY
All covered components - limited warranty for ve
years in residential applications, one year in non-
residential applications.
Refer to the Lennox Equipment Limited Warranty
certicate included with the unit for additional details.
APPROVALS
Units are UL listed per ANSI/UL 998 and CSA C22.2
No.104-01.
APPLICATIONS
Applicable to most forced air installations.
Installs on the supply air plenum with a by-pass duct
from the return plenum in up-ow and horizontal
applications. Installs on the return air plenum with a
by-pass duct from the supply plenum in down-ow
applications. See Typical Applications.
Provides additional humidity to the home during the
heating season to increase comfort level.
Do not install where freezing may occur.
Humidier, saddle valve and manual or automatic
humidier control (depending on model) shipped in one
package.
Sequence of Operation
Humidier will only operate when indoor blower is
operating.
When the level of moisture in the return air or living
space area drops below the set point of the humidier
control, the water solenoid valve opens, water ows
into distribution tray and weeps down through the
evaporator pad. By-pass air ows over the evaporator
pad, increasing the humidity of the air, and then back
into the return air stream. When the humidier control
is satised the water solenoid valve closes.
Cabinet
Rugged, corrosion resistant molded plastic.
Humidier is shipped for left-hand by-pass duct
connection.
For right-hand by-pass duct connection, rotate
humidier cabinet 180º top for bottom and relocate
drain spud. See Installation Instructions for additional
details.
Built-in damper included to close off bypass duct during
summer cooling operation.
E N G I N E E R I N G D ATA
Series
Controls
(blank) - Manual Humidistat
A = Automatic Humidier Control
Automatic Humidier Control
(furnished with “A” Models)
Manual Humidistat
(furnished with
standard Models)