1008 HEIDENHAIN Technical Manual iTNC 530 HSCI
Entries in the power
module table
(inverter.inv)
NAME: Designation of the power module
PWM: PWM frequency in [Hz] at which the power module is driven
S: Switch position of the current sensor. Is required for the D series of
HEIDENHAIN inverters (UM 1xx D) in order to use the higher currents
named above at the lower PWM frequencies.
Input 0 or 1
I-MAX: Maximum current of the inverter output in [A]
I-N: Rated current of the inverter output in [A]
U-IMAX: Current sensor voltage in [V] at I-MAX
I-N-DC: Permissible continuous current in stationary rotating field or until F-
DC is reached in [A]
T-DC: Time constant, how long maximum current can be applied to a
stationary synchronous motor in [s]
F-DC: Lower motor cutoff frequency down to which the motor can be loaded
with I-N-DC in [Hz]
T-AC: Cycle duration for the duty cycle S6-40% in [s]
F-AC: Motor frequency from which I-MAX is permissible in [s]
T-IGBT: Protection time of the IGBTs in [s]
R-SENSOR: Resistance of the current sensor. The entries in this column are
maintained by HEIDENHAIN and need not be changed by the machine tool
builder.
F-Limit: Lower frequency limit
Entries in the power
module table
(motor.amp)
Designation of power module (NAME)
Maximum current (I-MAX) in A
Rated current (I-N) in A at a PWM frequency of 5 kHz
Current sensor voltage (U-IMAX) in V at I-MAX
Permissible continuous current in stationary rotating field or until F-DC is
reached (I-N-DC) in A
Time constant, how long maximum current can be applied to a stationary
synchronous motor (T-DC) in seconds
Lower motor base frequency down to which the motor can be loaded with
I-N-DC (F-DC) in Hz
Cycle duration for the duty cycle S6-40%(T-AC) in seconds
Motor frequency from which I-MAX is permissible (F-AC) in seconds
Protection time of the IGBTs (T-IGBT) in seconds
Rated currents with PWM frequencies of 3333 Hz, 4000 Hz, 5000 Hz, 6666
Hz, 8000 Hz and 10000 Hz (I-N-AC-3333, I-N-AC-4000, I-N-AC-5000, I-N-AC-
6666, I-N-AC-8000, I-N-AC-10000) [A]