Entries in the motor
table (motor.mot)
A value that is not equal to 0 in a corresponding machine parameter replaces
the entry in the motor table.
Motor model (TYPE)
UASM = Uncontrolled asynchronous motor (volts-per-hertz control
mode)
SM = synchronous motor
ASM = asynchronous motor
LSM = linear motor
Designation of motor (NAME)
Operating mode (MODE)
Rated current (I-N) in A
Rated voltage (U-N) in V
Rated speed (N-N) in min
–1
Rated frequency (F-N) in Hz
No-load voltage (U0) in V
No-load current (I0) in A
Stator resistance cold (R1) in mΩ
Rotor resistance cold (R2) in mΩ
Stator leakage reactance (XStr1) in mΩ
Rotor leakage reactance (XStr2) in mΩ
Magnetizing reactance (XH) in mΩ
Upper speed X-H characteristic (N-XH) in min
–1
Threshold speed for field weakening (N-FS) in min
–1
Maximum speed (N-MAX) in min
–1
Factor for X-H characteristic (%-XH)
Factor for stalling torque reduction (%-K)
Number of pole pairs (PZ)
Temperature coefficient (TK) in Ω/K
Line count of the motor encoder (STR)
Encoder being used (SYS)
0 = No speed encoder (volts-per-hertz control mode)
1 = Incremental rotary encoder with Z1 track
2 = Absolute rotary encoder with EnDat interface (aligned
1
)
3 = Absolute linear encoder with EnDat interface
4 = Incremental linear encoder
5 = Absolute rotary encoder with EnDat interface (not aligned
1
)
6 = Incremental rotary encoder without Z1 track (one reference mark)
7 = Incremental rotary encoder with distance-coded reference marks
(not aligned
1
)
8 = Incremental linear encoder with distance-coded reference marks
(not aligned)
1. See "Field orientation" on page 1019.