July 2013 7.4 Single-speed, double-speed, PWM frequency 1077
Composition of the UEC 11x:
Useful configurations of UEC 11x:
MP2000.x Performance of control loop (software option 49)
Input: 0: Single-speed axis
1: Double-speed axis
DSP on drive-control motherboard
for max. five single-speed (SS) axes
Controller group 1
(on drive-control
motherboard CB)
Controller group 2
(controller expansion
board1CE1)
Controller group 3
(controller expansion
board 2 CE 2)
X80 (SS)
Spindle
X81 (SS)
Axis
X82 (SS)
Axis
X83 (SS)
Axis
X84 (SS)
Axis
Vacant
Number of single-speed axes: Number of double-speed axes:
5 single-speed 0 double-speed
4 single-speed
(X80, X81, X82, X83)
1 double-speed
(X84)
3 single-speed axes
(X82, X83, X84)
1 double-speed spindle
(X80)