July 2013 7.10 Adjustment of linear and torque motors 1127
Attention
Please comply with the following instructions during all servicing work:
Mounting, servicing for initial operation, and maintenance are to be
performed only by trained personnel.
Wear work gloves during installation and maintenance work.
Persons with pacemakers must not service the machine.
Keep clocks and magnetized data media (e.g. credit cards, floppy disks,
etc.) at a distance.
Do not allow heavy metallic objects to contact the secondary winding of
the motor.
Never allow magnetic surfaces to contact metal.
Never place the primary winding directly onto the secondary winding.
Keep a good grip on steel tools and bring them to the secondary winding
only slowly and from the side.