1154 HEIDENHAIN Technical Manual iTNC 530 HSCI
Error code:
Marker Value Meaning
M4203 0 No error
1 Faulty execution of module
W1022 2 No rotary axis transferred, or impermissible feed rate
or open-loop axis programmed
9 Other traversing command active for axis at start of
function
21 No M/S/T/Q strobe during started program
33 Axis has not traversed the reference mark
Set Reset
M4133 Start and stop the free rotation
function
PLC NC
B518 Definition of the free rotation
function
0: Cancel the function
8: Free rotation for axis 4
16: Free rotation for axis 5
PLC PLC
B519 Traverse direction for free rotation
0: Axis 4 and axis 5 = +
8: Axis 4 = – , axis 5 = +
16: Axis 4 = +, axis 5 = –
24: Axis 4 and axis 5 = –
PLC PLC
W754 % function for feed-rate override for
free rotation
PLC PLC
W566 - 568 Feed rate for free rotation
Axis 4 to axis 5
PLC PLC