1158 HEIDENHAIN Technical Manual iTNC 530 HSCI
M functions of the PLC can be displayed in the status window:
With Module 9088 you can display M functions in the status window or
delete them.
Module 9088 Display the M functions
Call:
PS B/W/D/K <Number of the M function to be displayed>
PS B/W/D/K <Mode>
–1: Delete all M functions in the status window
0: Delete M function
1: Display M function
CM 9088
Error code:
M functions of the NC
M functions of the PLC
(displayed via Module 9088)
Marker Value Meaning
M4203 0 M function displayed or deleted
1 Error code in W1022
W1022 1 Invalid M-function number