1162 HEIDENHAIN Technical Manual iTNC 530 HSCI
Interrogating the
status display
through the PLC
Module 9035 Read status information
With this module you can interrogate the status display or read the status
information. You transfer a number indicating the desired information. In order
to receive information about the status of the alternative smarT.NC operating
mode, please use the operating mode markers or the operating mode word
(see "Operating modes" on page 1165).
Transferred number Return code
0 Editor mode in foreground 0: Programming and Editing
1: Test Run
1 Machine mode in foreground 0: Traverse reference points
1: Manual operation
2: Electronic Handwheel
3: Positioning with Manual Data Input
4: Program Run, Single Block
5: Program Run, Full Sequence
2 Editor mode in background 0: None (main operating mode active)
1: MOD active
2: Program management/external interfaces active
3: MP editor active
4: PLC programming active
3 Machine mode in background 0: None (main operating mode active)
1: MOD active
2: Program management/external interfaces active
3: Tool table selected
4: Pocket table selected
5: Other table editor active
4 Displayed screen window Bit encoded
Bits 0 to 7: Editing screen
Bit 0=1: Editing screen is displayed
Bit 1=1: Operating-mode window active
Bit 2=1: Block display/program select/setup window
active
Bit 3=1: Position display active
Bit 4=0: Always 0 / Not possible
Bit 5=1: Status/Graphics window active
Bits 6/7: Reserved
Bits 8 to 15: Machining screen
Bit 8=1: Machining screen is displayed
Bit 12=1: PLC status window active in machining
screen
Bits 9 to 15: Reserved
5 Selected file in Programming and
Editing or Test Run
0: No file
1: *.H (conversational NC PGM)
2: *.I (ISO NC PGM)
3: *.T (tool table)
4: *.D (datum table)
5: *.P (pallet table)
6: *.A (ASCII file)
7: *.TCH (pocket table)
6 Selected file in Program Run, Full
Sequence and Program Run, Single
Block
0: No file
1: *.H (conversational NC PGM)
2: *.I (ISO NC PGM)