July 2013 8.1 Display and operation 1173
Module 9194 Alarm when operating time exceeded
You define a marker that is set when a certain threshold is exceeded. The
marker is set every minute after the threshold is passed. The marker can be
delayed by max. 59 s the first time it is set. All values greater than
2 147 483 648 (approx. 69 years) must be transferred as negative numbers.
If you enter the value zero as the alarm threshold, the function is deactivated.
Call only in a submit job or spawn job.
Call:
PS B/W/D/K <Number of the operating time>
–3: Control on
–2: Machine on
–1: Program run
0 to 12: PLC operating times 1 to 13
PS B/W/D/K <Alarm threshold [s]>
PS B/W/D/K <Number of the alarm marker>
CM 9194
Error code:
Marker Value Meaning
M4203 0 Alarm function activated
1 Incorrect transfer value, or module was not called in a
spawn or submit job