July 2013 8.1 Display and operation 1175
Module 9055 Local time
With Module 9055 you can convert the value read with Module 9195 into a
legible ASCII format. Module 9055 corrects the transferred value to local time.
Call:
PS B/W/D/K <System time>
Number of seconds since 0:00 hours on January 1, 1970.
PS B/W/D/K <String number for the result>
PS B/W/D/K <Format>
0: DD.MM.YYYY hh:mm:ss
1: D.MM.YYYY h:mm:ss
2: D.MM.YYYY h:mm
3: D.MM.YY h:mm
4: YYYY-MM-DD- hh:mm:ss
5: YYYY-MM-DD- hh:mm
6: YYYY-MM-DD h:mm
7: YY-MM-DD- h:mm
8: DD.MM.YYYY
9: D.MM.YYYY
10: D.MM.YY
11: YYYY-MM-DD
12: YY-MM-DD
13: hh:mm:ss
14: h:mm:ss
15: h:mm
CM 9055
Error code:
Marker Value Meaning
M4203 0 String was created
1 Incorrect transfer value